The P14TY is a refrigerant compressor model listed in the provided datasheet, designed for use in refrigeration or air conditioning systems. Below is a summarized technical breakdown of its key specifications:


P14TY Compressor Specifications

Parameter Value Notes
Model P14TY Part of a series (likely Panasonic or similar brand).
Power (HP) 3/8 HP ~0.375 horsepower.
Displacement 14.00 cm³ Cylinder volume per revolution.
Refrigerant R12 (CFC) Older refrigerant (now phased out; check local regulations).
Cooling Capacity – W: 985 W
– kcal/h: 996
– BTU/h: ~3,360
At -25°C evaporating temp (CECOMAF conditions).
COP (Efficiency) 1.73 (W/W) Coefficient of Performance.
Oil Type/Volume 400 cm³ Mineral or alkylbenzene oil (for R12).
Weight 11.5 kg
Motor Type CSIR (Capacitor Start, Induction Run) Single-phase operation.
Starting Method Relay (R)
Voltage/Frequency 220-240V, 50Hz Single-phase AC.
Expansion Type Capillary tube (C) or Valve (V) Configurable based on application.

Key Observations

  1. Refrigerant (R12):
    • The P14TY is designed for R12, an obsolete CFC refrigerant banned under the Montreal Protocol due to ozone depletion. Modern alternatives (e.g., R134a, R404A) require retrofitting or replacement.
  2. Applications:
    • Likely used in medium-temperature refrigeration (e.g., commercial refrigerators, chillers) given its capacity and COP at -25°C evaporating temperature.
  3. Efficiency (COP 1.73):
    • Lower COP compared to modern compressors, indicating higher energy consumption.
  4. Replacement Considerations:
    • If retrofitting for alternative refrigerants, ensure compatibility with oil type (e.g., POE for HFCs) and system components.
    • Verify electrical specs (voltage, starting torque) for new installations.

Testing Conditions (CECOMAF/ASHRAE)

  • Evaporating Temp: -25°C (LBP testing for low-temperature applications).
  • Condensing Temp: 55°C.
  • Ambient Temp: 32°C.

Actionable Recommendations

  • For Maintenance:
    • Check oil levels and contamination if still using R12.
    • Inspect capacitors/relays (common failure points in CSIR motors).
  • For Replacement:
    • Consider modern equivalents (e.g., Panasonic/Copeland models for R404A/R134a).
    • Consult HVAC technician for system compatibility and retrofitting.