R134a QB Series PANASONIC Air Conditioner Compressor ,ALL Application & Refrigerant LBP R134a
general data
Operating voltage: 220V 50Hz
Freon type: 134a
Application type: LBP (low heat)
Piston Engine Type: (RSIR) Resistive Start Induction Run
xx in the piston code number indicates piston displacement
Performance and operation data in a temperature range from -15 to -30 and cooling capacity in watts
Model | displacement cc | -30 | -25 | -23.3 | -20 | -15th | Oil volume cm3 |
QB66C13GAX5 | 6.55 | 108 | 149 | 165 | 200 | 263 | …./250 |
QB73C15GAX5 | 7.27 | 121 | 167 | 185 | 224 | 294 | 250/300 |
QB77C16GAX5 | 7.69 | 131 | 182 | 202 | 245 | 319 | 250/300 |
QB86C18GAX5 | 8.56 | 145 | 200 | 222 | 268 | 347 | 250/300 |
154 | 213 | 236 | 285 | 372 | 250/300 | ||
QB110C25GAX5 | 10.86 | 176 | 246 | 273 | 331 | 432 | 250/300 |
NB
1- The volume of oil needed for the piston increases from 250 to 300 in the case of static condenser (cooling air).
2- The cooling capacity in the table under the following conditions:
Condensing temperature = 54.4 Celsius
Outside temperature = 32.2 Celsius
Sub-cooling temperature = 32.2 Celsius
Mbsm_dot_pro_private_PDF_QB86C18GAX5