The AGC5568EXG compressor has a capacity of 5.5 horsepower, which translates to approximately 4 tons of refrigeration. However, it’s important to note that the exact tonnage can vary depending on several factors, including:
Evaporating temperature: The compressor’s capacity is typically rated at a specific evaporating temperature, usually around 45°F (7°C). If your application operates at a different temperature, the actual tonnage will be higher or lower.
Condensing temperature: The condensing temperature also affects the compressor’s capacity. Higher condensing temperatures will result in lower tonnage.
Refrigerant type: The AGC5568EXG is designed for use with R22 refrigerant, but it may also be compatible with other refrigerants. However, the capacity will vary depending on the specific refrigerant used.
Therefore, to get the most accurate estimate of the AGC5568EXG’s tonnage for your specific application, it’s best to consult the manufacturer’s technical data sheet or contact a qualified refrigeration technician. They can consider all the relevant factors and provide you with a more precise tonnage calculation.
Product Family
AG144UT-001-J7 compressor R22 460V 3ph 5-1/2 HP air conditioning
A low-pressure cut-off switch is a safety device used in various applications to protect equipment from damage caused by low pressure. They are commonly found in:
Water pumps: In well water systems, a low-pressure cut-off switch prevents the pump from running dry, which can overheat and damage the pump. When the water pressure falls below a set point, the switch turns off the pump.
Lowpressure cutoff switch for water pumps
Refrigeration systems: In refrigerators and air conditioners, a low-pressure cut-off switch protects the compressor from damage if the refrigerant level falls too low. This can happen due to a leak or a malfunction.
Lowpressure cutoff switch for refrigeration systems
Air compressors: In air compressors, a low-pressure cut-off switch prevents the compressor from overheating if the air pressure falls below a set point. This can happen if there is a leak in the system or if the compressor is not properly lubricated.
Lowpressure cutoff switch for air compressors
Oil burners: In oil burners, a low-pressure cut-off switch prevents the burner from operating if the oil pressure falls below a set point. This can happen if there is a leak in the oil line or if the oil filter is clogged.
Low-pressure cut-off switches are typically adjustable, so the pressure at which they trip can be set to meet the specific needs of the application. They are a vital safety device that can help to prevent costly damage to equipment.