LG rotary, compressor, model, QJS222PMA, 12700BTU 5.6Amps, EER = 10.7, air conditioner
written by Lilianne | 11 April 2021
Product details LG rotary compressor model QJS222PMA size 12700BTU (5.6Amps, EER = 10.7)
LG rotary compressor model QJS222PMA size 12700BTU (5.6Amps, EER = 10.7)
generation
Equivalent to
BTU
Running still (MFD)
electricity
QJS222PMA
RH-207 (TOPTECH)
12700
40 / 440V
220V / 1PH / 50Hz
PH360G2C-4FTS1, 22000BTU, GMCC, Compressor rotary, 2 Ton, air conditioner, R22, refrigeration compressor , 50HZ 220V / 240V
written by Lilianne | 11 April 2021
product description
Product Specification
Air Tank Capacity
2 Ton
Brand
BLUESTAR
Refrigerant
1.8 kg
Capacity
24840 Btu/Hr
Color
Black
I deal in
New Only
BSL CODE
CMROS220K1100
COMPRESSOR OPERATE ON
220-240V
COP
4.52 (w/w)
Capillary Size
1 way x 2.03mm x 508mm
Nominal Power input
2.15 HP & 1.6 KW
Oil Qty
700 cc
Run Cap
55/400 mF/VAC
Minimum Order Quantity
10
Copeland compressor related parameters
model
Volt support: V/phase
Replacement effect: cc/rev
Horsepower: HP
Cooling capacity: Btu
Input power: W
Rated load amplifier: A
Locked rotor ampere:
Oil change: L
ZR61KC-TFD-522
380V/460V50Hz/60Hz; 3P
82.6
5
61880
5400
11
63
1.95
ZR72KC-TFD-522
380V/460V50Hz/60Hz; 3P
98.1
6
73500
6250
13
75
1.77
ZR81KC-TFD-522
380V/460V50Hz/60Hz; 3P
107.8
6.8
82000
6950
15
100
1.77
ZR84KC-TFD-522
380V/460V50Hz/60Hz; 3P
113.6
7
85500
7300
15
100
2.51
ZR94KC-TFD-522
380V/460V50Hz/60Hz; 3P
127.2
7.8
96500
8200
16
95
2.51
ZR108KC-TFD-522
380V/460V50-60Hz; 3P
142.9
9
109000
9200
17
114
3.25
ZR125KC-TFD-522
380V/460V50Hz/60Hz; 3P
167.2
10
128000
10900
19
125
3.25
ZR144KC-TFD-522
380V/460V50Hz/60Hz; 3P
190.9
12
146000
12300
twenty two
125
3.25
ZR160KC-TFD-522
380V/460V50Hz/60Hz; 3P
209.1
13
160000
13,900
28
138
3.25
ZR190KC-TFD-522
380V/460V50Hz/60Hz; 3P
249.2
16
190000
16,800
34
173
3.25
ZR250KC-TWD-522
380V/460V50Hz/60Hz; 3P
325.2
20
249900
21700
30
225
4.67
ZR310KC-TWD-522
380V/460V50Hz/60Hz; 3P
410.6
25
306000
27100
38
272
6.80
ZR380KC-TWD-522
380V/460V50Hz/60Hz; 3P
502.7
32
379000
32700
45
310
6.30
GMCC rotary compressor 1. Higher energy efficiency The compressor COP is 395% under the conditions of WEER6O 2. Higher heating capacity Relative improvement of heating capacity at an ambient temperature of -15℃ by 20%-50% 3. Improved low temperature adaptabilityHigh outlet air temperatures at anambient temperature of -20℃ 4. Strong power Sub-Class-2 compression technology thatprovides strong power 5. High level of serialization Gas injection technology applied to thewhole lineup of 1HP-5HP
GMCC Compressor 220/240V 50Hz
Model
Displacement
Cooling Capacity
Power
Cop
Compressor Height
W
Btu/h
W
W/W
mm
PH300G2C-4KU1
29.8
5340
18220
1645
3.25
297
PH310G2C-4KU1
30.8
5515
18817
1695
3.25
310
PH340G2C-4KU1
33.7
6030
20575
1865
3.23
310
PH340G2C-4KU
33.7
6050
20643
1805
3.35
310
PH360G2C-4KU1
36
6475
22093
2005
3.23
324
PH370G2CS-4KU1
37
6650
22690
2065
3.22
324
PH370G2C-4KU
37
6660
22724
2020
3.3
324
PH400G2CS-4KU1
39.8
7100
24226
2255
3.15
354
PH400G2C-4KU
39.8
7095
24209
2215
3.2
354
PH420G2CS-4KU1
42.3
7420
25318
2390
3.1
354
PH420G2C-4KU
42.3
7555
25778
2365
3.2
354
PH440G2C-4KU
43.5
7810
26648
2390
3.27
354
PH460X3CS-4MU1
45.9
8080
27569
2600
3.1
396.5
PH480X3CS-4MU1
47.9
8460
28866
2730
3.1
396.5
Factory directly supply GMCC R22 T3 Air Conditioner Rotary Compressor 50HZ 220V/240V to Colombia Factories
Product Detail
Series
Typical model
Displ.
Cooling Capacity
Power
COP
Capacitor
Compressor Height
Discharge Pipe ID
Sucition Pipe ID
Remark
(cc)
(w)
(Btu/h)
(w)
(W/W)
(μF/V)
(mm)
(mm)
(mm)
1Φ-50HZ-220/240V
M2
PH200M2A-4FTS1
19.9
3555
12130
1095
3.25
35/370
292
8.2
12.9
PH210M2A-4FTS2
20.9
3765
12846
1160
3.25
35/370
292
8.2
12.9
PH310M2AS-4KTS1
31.0
5620
19175
1755
3.20
50/370
348
9.8
12.9
G2
PH340G2C-4KTS1
33.7
6050
20643
1890
3.20
60/400
310
9.8
12.9
PH360G2C-4FTS1
36.0
6455
22024
2015
3.20
60/400
324
9.8
16.2
PH400G2C-4KTS1
39.8
7080
24157
2250
3.15
60/400
354
9.8
12.9
PH420G2C-4KTS1
42.3
7540
25726
2370
3.18
60/400
354
9.8
12.9
PH440G2C-4KTS1
43.5
7685
26221
2500
3.07
60/400
354
9.8
12.9
Products Feature
1.Full range of product models with a wide application field
2.Covering the 1~3HP constant-voltage variable-frequency product series
3.Environment friendly, safe, efficient and economical
Pressure and boiling Temperature list, standing, Refrigerant, suction, discharge
written by Lilianne | 11 April 2021
Pressure and boiling Temperature list, standing, Refrigerant, sustion, discharge
no frost, egl99aa zmc refrigerator, DF40, silver, ideal, zanussi, IDEAL ZANUSSI, EGL99AA ZMC, DF 40 Elgance, Compressor, ACC Cubigel, Huayi, Electrolux, ZEM GL99AA, GL99AA, LBP , R134a, 220-240V/1/50Hz, 1/4 HP, discharge 9.93 cm3, motor type RSIR, LRA 14.4A
Compressor ACC Cubigel Huayi Electrolux ZEM GL99AA, LBP – R134a, 220-240V/1/50Hz, 1/4 HP, discharge 9.93 cm3, motor type RSIR, LRA 14.4A, expansion device: capillary, cooling: static,weight 11 kg , the statutory warranty period shall apply (24 months), Delivery time Info: with “immediately available” and “scarce stock”, usually delivery within 2 days. For “currently not available” delivery time usually 2 weeks or delivery time in urgent cases contact us.
Types of Electrical Motors RSIR (Resistance Start-Induction Run) LST motor. No capacitors. Auxiliary winding is disconnected after start up. Standard energy efficiency. CSIR (Capacitor Start-Induction Run) HST motor. With starting capacitor. Auxiliary winding is disconnected after start up. Standard efficiency. RSCR (Resistance Start-Capacitor Run) LST motor. With running capacitor. Auxiliary winding remains connected after start up. Used for high efficiency in small capacity compressors (particularly in household refrigeration) CSR (Capacitor Start and Run) HST motor. Two capacitors (starting and running). Auxiliary winding remains connected after start up. Used for high efficiency in small compressors and for size reduced size motors in compressors with comparatively large displacements
Type of starting device Current relay – (electromechanical). RSIR/CSIR motors and CSR low/ medium-power motors with NTC (the NTC is connected in series with the starting capacitor and the main purpose is to reduce the current peaks in the relay contacts) Potential relay – (electromechanical). CSR high-power motors. PTC – (Positive Temperature Coefficient), the resistance increases with the temperature. Device only with RSIR or RSCR motors in the (Small L, B), L and P ranges. NTC – (Negative Temperature Coefficient), the resistance decreases with the temperature. Used in some CSR in order to reduce dimensions and components.
Type of torque LST – Low Starting Torque – Systems with capillary tube or balanced pressures at start up. HST – High Starting Torque – Systems with expansion valve or capillary tube, with unbalanced pressures at start up.
Catalogue, DANFOSS, All Compressor, PDF Catalogs, Documentation
written by Lilianne | 11 April 2021
Catalogue, DANFOSS, All Compressor, PDF Catalogs, Documentation