ENIEM Refrigerateur, no-frost, Made in Algeria, 540L, 220v-240v/50hz, Inverter, Compressor , Technology , Refrigerator LG, bsa090njmv, Inverter, Small Compressor, 9.8 cc , r600a, 60G, Block dc control inverter
written by Lilianne | 13 January 2021
ENIEM Refrigerateur, Made in Algeria, 540L, 220v-240v/50hz, Inverter, Compressor , Technology , Refrigerator LG, bsa090njmv, Inverter, Small Compressor, 9.8 cc , r600a, Block dc control inverter
Description du compresseur GMCC Les compresseurs de
climatisation GMCC réduisent les coûts pendant toute la durée de vie du produit dans l’application. Ils prennent en charge la conception de systèmes pour des performances à haut rendement et pour l’utilisation de réfrigérants alternatifs pour les applications HVAC commerciales, commerciales et industrielles légères telles que les unités de toit, les refroidisseurs, le refroidissement de processus, les unités emballées, etc.
Compresseur Toshiba GMCC A / C R22 220-240V / 50HZ / 1PH
Données du compresseur Compresseur: PH440X3CS-4MU1 Réfrigérant: R22 Type de compresseur : Compresseur à moteur hermétique Type de pompe: Huile rotative préchargée: FV50S 900cm³ N.W .: 22,2KG
Conditions nominales Température d’évaporation ARI : 7,2 ° C Température de condensation: 54,4 ° C Température du gaz de retour: 18,3 ° C Temp du liquide: 46,1 ° C Ambiante, air au-dessus: 35 ° C , 1m / s
Liste des accessoires standard Couvre- bornes Cache -bornes Joint Écrou-Cache-borne Écrou Joint caoutchouc Grommet ressort
Danfoss Maneurop NTZ series compressors are hermetic reciprocating type and designed for low evaporating temperature applications.Refrigerant:R404A/R507A
Danfoss Maneurop MT/MTZ series compressors are hermetic reciprocating type and designed for Medium and High evaporating temperature applications. Refrigerant;R22,R407C, R134A, R404A
380-400V/3~/50Hz and 460V/3~/60Hz
Models:MT/MTZ018 MT/MTZ022 MT/MTZ028….MT/MTZ320
Danfoss Maneurop MPZ series compressors are hermetic reciprocating type and designed for Medium and High evaporating temperature applications. Refrigerant:R404A/R507A
Kulthorn, compressor, Kulthorn compressor, c-qn76l6f, 1/10 Hp, 1Ph, Serie C-q, R134a, 76 watt, Low back pressure, 200-220V/50hz, 220v/60hz, Compressor modefier
Compressor Motor Protectors Each compressor incorporates a motor protection device or system. Generally, the larger the compressor, the more sophisticated the motor protector. It is essential that an electric motor is protected against conditions that could otherwise result in damage to the motor or to the electrical supply system. For this reason, every Kulthorn compressor is supplied with a motor protector, sometimes referred to as an overload. The more expensive the compressor, the greater is the economic justification for specifying a motor protector that has the ability to protect over a wider range of conditions.
External Motor Protectors A smaller compressor (such as an AZ, AE or WJ) is fitted with an external motor protector. Most commonly, this is a compact, cylindrical device that contains a snapaction bimetallic disc. The protector is mounted in contact with the surface of the compressor housing, inside the terminal guard. The compressor current passes through the bimetallic disc. The resistance of this disc causes the disc temperature to increase as the motor current increases. There is usually a small heater, located under the disc and connected in series with the disc itself. This heater further raises the temperature of the disc. There is also the impact of the compressor shell temperature, and a hot compressor will further increase the disc temperature. The temperature of the disc is thus influenced by the combined effects of – • the compressor motor current • the compressor shell temperature When the bimetallic disc reaches a predetermined temperature (often either 105°C or 120°C) the disc will snap open, and power supply to the compressor will be interrupted. The compressor will cool, and at a reduced disc temperature the protector will reset and the compressor will restart, or attempt to restart. If the abnormal condition that caused the protector to trip in the first place still exists, the compressor is likely to continue to cycle on the overload until that condition is corrected. There are two situations where a motor protector is expected to operate.
When the compressor is running under extreme conditions.
When the compressor is in a locked rotor condition. This is a situation where the compressor cannot start because the voltage is too low, the system pressures are outside the range for which the compressor is approved, there is internal damage to the compressor, or there is some other reason why the compressor is incapable of starting