AEA3440YXC ,Tecumseh Product Co ,HBP ,Moteur HP , 1PHase, 1/3HP , High Back Pressure ,R134a ,220-240V ~ 50Hz ,Reciprocating Compressor ,996W

HBP – High Back Pressure R134a 220-240V ~ 50Hz Reciprocating Compressor

Product Description
 
Type Reciprocating
 
Application HBP – High Back Pressure
 
Refrigerant R134a
 
Voltage/Frequency 220-240V ~ 50Hz
Product Specifications
 
Performance
 
Condition ARI
 
Test Voltage 220V ~ 50HZ
 
Refrigeration Capacity
 
Btu/h 3400
 
kcal/h 857
 
W 996
 
Input Power
 
W 520
 
Efficiency
 
Btu/Wh 6.5400
 
kcal/Wh 1.6500
 
W/W 1.9200
 
Evaporator Temperature 7.2°C (45°F)
 
Condensing Temperature 54°C (130°F)
 
Ambient Temperature 35°C (95°F)
 
Return Gas Temperature 18.3°C (65°F)
 
Liquid Temperature 46°C (115°F)
 
General
 
Evaporating Temperature Range -6.7°C to 12.8°C (20°F to 55°F)
 
Motor Torque Low Start Torque (LST)
 
Compressor Cooling Fan
 
Mechanical
 
Displacement (cc) 12.0450
 
Oil Type Polyolester
 
Viscosity (cSt) 32
 
Oil Charge (cc) 303
 
Sound Power dB(A) 0
 
Electrical
 
Voltage Range (50 Hz) 198-264
 
Voltage Range (60 Hz) N/A
 
Locked Rotor Amps (LRA) 0
 
Rated Load Amps (RLA 60 Hz) 0
 
Maximum Continuous Current (MCC in Amps) 0
 
Motor Resistance (Ohm) – Main 0
 
Motor Resistance (Ohm) – Start 0
 
Motor Type RSIR
 
Overload Type N/A
 
Relay Type N/A
 
Agency Approval CSA Listed, UL Recognized



DAEWOO Compressor , HSL25YE-5, 1/4HP, 1PH, R134a ,220-240V 50Hz, Puissance frigorifique, 204 W ,690 BTU

 

 

 




PDF : Calcul ,désenfumage ,pour immeuble

احتساب دخان المبنى

note de calcul désenfumage pour immeuble contient atrium

smoke extraction calculation for building contains atrium

Règle de calcul de la surface utile des évacuations de fumée nécessaire au désenfumage d’un local

Les surfaces prises en compte pour l’évacuation des fumées doivent se situer dans la zone enfumée. Les surfaces prises en compte pour les amenées d’air doivent être dans la zone libre de fumées. La répartition des amenées d’air doit assurer un balayage satisfaisant du local.

1° Locaux de superficie inférieure ou égale à 1 000 m2 :

Dans le cas où la superficie des locaux à désenfumer n’excède pas 1 000 m2, la surface utile des évacuations de fumée doit correspondre au 1/200 de la superficie du local mesurée en projection horizontale. Toutefois, cette surface peut être limitée à la valeur de la surface utile calculée au moyen du tableau de l’annexe, pour un local de 1 000 m2 ayant la même hauteur de référence et la même épaisseur de fumée.

La surface libre totale des amenées d’air d’un local doit être au moins égale à la surface géométrique des évacuations de fumée de ce local.

Lorsque le désenfumage de locaux de superficie inférieure à 300 m2 est exigé par les dispositions particulières, une fenêtre peut compter pour une bouche d’amenée d’air et/ou d’évacuation de fumée ; la surface libre prise en compte pour l’évacuation des fumées doit se situer dans la moitié supérieure du local et être à plus de 1,80 m du plancher. La surface libre prise en compte pour l’amenée d’air doit se trouver en dehors de la zone précédemment définie pour l’évacuation.

(figure 11)

2° Locaux de superficie supérieure à 1 000 m2 :

La surface utile des évacuations de fumée est déterminée par type d’exploitation (dont dépend la surface du feu) en fonction de la hauteur de référence (H) et de l’épaisseur de la couche de fumée (Ef).

Cette surface est obtenue en multipliant la superficie de chaque canton par un taux(en pourcentage), elle ne doit jamais être inférieure à celle calculée pour un canton de 1 000 m2. L’annexe donne un tableau des valeurs de ce tauxet les deux formules qui permettent de le calculer.

Dans le cas où la toiture (ou le plafond suspendu) d’un canton est horizontale mais présente des discontinuités de hauteur, le calcul de cette surface utile est effectué par canton en prenant pour hauteur de référence la hauteur de la partie la plus haute du canton. La surface utile des évacuations situées dans les autres parties est corrigée dans les conditions du 3° du présent paragraphe.

(figure 12)

Dans le cas de locaux comprenant un seul canton, la surface libre totale des amenées d’air doit être au moins égale à la surface géométrique totale des évacuations de fumée.

Dans le cas de locaux divisés en plusieurs cantons, cette amenée d’air peut se faire par les cantons périphériques. La surface libre des amenées d’air doit être au moins égale à la somme des surfaces géométriques des évacuations de fumée des deux cantons exigeant les plus grandes surfaces utiles d’évacuation.

3° Correction des surfaces utiles des évacuations de fumée des locaux de superficie supérieure à 1 000 m2 :

La surface utile d’un exutoire doit être minorée ou majorée en la multipliant par un coefficient d’efficacité suivant que l’exutoire est implanté au-dessous ou au-dessus de la hauteur de référence. Dans ce dernier cas, la longueur des conduits de raccordement verticaux éventuels est limitée à 10 diamètres hydrauliques sauf justification par le calcul pour des longueurs supérieures (diamètre hydraulique = 4 x section du conduit/périmètre du conduit).

(figure 13) (H positif)

Ce coefficient d’efficacité (e) dépend de l’épaisseur de la couche de fumée (Ef) et de la différence de hauteur (H) (positive ou négative) d’implantation de l’exutoire par rapport à la hauteur de référence suivant la formule :

e = (1 + H/Ef)¹/2

Le même coefficient d’efficacité s’applique à la surface utile des bouches d’évacuation.

Pour un ouvrant en façade, ce coefficient d’efficacité s’applique à la surface utile de l’ouvrant situé dans la zone enfumée ; la valeur H représente la différence de niveau entre la hauteur de référence et la moyenne des hauteurs des points hauts et bas de la partie d’ouvrant située en zone enfumée.

(figure 14) (H négatif)

Lorsqu’un local est désenfumé uniquement par des ouvrants en façade situés à la même hauteur, cette correction n’est pas utile si la moyenne des points hauts et bas est considérée comme hauteur de référence.

(figure 15)

Figures

    



Danfoss ,Fridge Compressor ,NL7FT , 1/4 HP ,R134a

   R404A/R507 • R134a • R290
 
Danfoss Compressors
 
R404A/R507 • R134a • R290 
 
REFRIGERATION & AIR CONDITIONING DIVISION
 
——–
 
Refrigerant
Frequency
Compressor Code numbers Horsepower EN 12900 (CECOMAF) EN 12900 (CECOMAF) DisplaceCompressor
Compressor (approx.) Capacity [W] Power consumption ment
with [W]
oil
cooling Evaporating temperature [°C] Evporating temp. [°C]
-45 -40 -35 -30 -25 -23.3 -20 -15 -10 -5 -25 -10 [cm3
]
R134a
50 Hz
101G0220 1/12 14 26 40 45 56 74 95 60 86 2.50 PL50F
TLS3FT 102G4324 1/10 21 34 50 56 69 92 120 62 92 3.13
TLS4FT 102G4424 1/8 27 43 63 71 88 117 152 87 123 3.86
TLS5FT 102G4524 1/6 48 71 98 109 131 170 216 114 165 5.08
NL6FT 105G6628 1/5 60 84 115 127 152 198 253 123 184 6.13
NL7FT 105G6728 105G6738 1/4 71 100 136 150 181 235 299 145 220 7.27
 
 
 
NL9FT 105G6828 105G6838 1/3 87 120 162 178 213 275 350 169 252 8.35
 
 
 
 
 
NL10FT 105G6829 105G6839 3/8 113 158 213 235 281 361 455 217 327 10.10
SC12FT 104G8205 104G8215 3/8 103 163 233 259 314 408 517 645 265 380 12.87
SC15FT 104G8505 1/2 126 197 280 311 376 489 620 772 311 451 15.28
SC18FTX 104G8805 5/8 144 229 325 361 437 567 719 896 365 517 17.68
SC21FTX 104G8105 3/4 192 296 415 460 553 713 901 1119 428 613 20.95
60 Hz
PL35G 101G0250 1/16 34 39 48 64 82 104 52 79 2.00
TL2.5G 102G4251 1/16 14 27 42 48 60 80 105 134 67 96 2.61
TL3G 102G4350 1/12 30 47 54 69 95 125 70 111 3.13
TL4G 102G4452 1/10 48 70 78 96 127 166 87 135 3.86
TL5G 102G4550 1/8 65 92 102 123 162 207 106 170 5.08
FR6G 103G6660 1/6 51 93 108 141 199 266 119 197 6.23
FR7.5G 103G6680 103G6690 1/5 67 112 130 166 228 300 138 229 6.93
FR8.5G 103G6780 103G6790 1/4 92 138 156 195 263 345 164 273 7.95
FR10G 103G6880 103G6890 1/3 99 153 173 217 292 381 194 314 9.05
SC12FT 104G8205 104G8215 1/2 125 192 272 302 366 477 608 761 298 458 12.87
SC15FT 104G8505 5/8 154 235 330 365 441 571 724 904 356 537 15.28
SC18FTX 104G8805 3/4 187 280 390 432 520 675 857 1071 420 622 17.68
SC21FTX 104G8106 7/8 240 345 470 518 620 800 1012 1262 475 707 20.95
R404A/R507
50 Hz
TL4CL 102U2071 1/8 52 65 84 110 142 155 182 230 286 352 140 198 3.86
FR6CL 103U2670 1/6 77 108 145 189 243 263 307 383 473 578 242 353 6.23
FR7.5CL 103U2790 1/5 86 114 154 202 262 285 333 418 515 630 267 395 6.93
FR8.5CL 103U2890 1/4 99 126 168 222 290 317 372 468 577 315 472 7.95
NL7CLX 105F3710 1/3 102 146 199 263 340 369 430 536 657 796 274 381 7.27
SC10CLX 104L2533 1/3 166 255 360 400 483 625 789 977 352 508 10.29
SC12CL 104L2623 3/8 58 140 237 353 490 541 650 835 1048 1292 445 654 12.87
SC12CLX.2 104L2697 1/2 130 205 294 399 522 569 666 834 1026 475 659 12.87
SC15CL 104L2853 1/2 151 299 452 615 673 792 988 1208 1458 560 790 15.28
SC15CLX.2 104L2896 1/2 159 250 358 486 637 694 813 1017 1251 1519 565 783 15.28
SC18CL 104L2123 5/8 167 271 395 542 715 781 918 1154 1425 1735 615 894 17.68
SC18CLX.2 104L2197 3/4 194 306 439 595 780 849 995 1245 1532 680 949 17.68
SC21CL 104L2322 7/8 226 325 455 617 813 887 1042 1306 1606 702 989 20.95
GS26CLX 107B0500 1 325 497 703 949 1240 1348 1580 1974 2427 888 1285 26.30
GS34CLX 107B0501 1 1/4 729 1003 1330 1715 1857 2165 2687 3289 1196 1721 33.80
60 Hz
SC10CLX 104L2533 3/8 224 335 455 499 588 738 906 1096 430 623 10.29
SC12CLX 104L2695 1/2 146 282 429 590 649 770 972 1200 540 748 12.87
SC12CLX.2 104L2697 1/2 155 233 343 473 626 683 804 1011 1248 541 777 12.87
SC15CLX 104L2854 5/8 179 351 530 720 788 928 1158 1417 610 864 15.28
SC15CLX.2 104L2897 5/8 194 305 437 593 776 846 991 1239 1525 611 848 15.28
SC18CLX.2 104L2195 7/8 113 338 542 737 938 1010 1157 1410 1708 752 990 17.68
GS21CLX  107B0506 1 475 674 905 1172 1270 1480 1873 2246 868 1180 21.20
R290
50 Hz
TL3CN  102H4380 1/10 106 200 106 140 3.13
TL4CN  102H4490 1/8 56 126 255 128 155 3.86
TL5CN 102H4590 1/6 81 109 143 183 198 230 283 345 416 162 211 5.08
NL7CN 105H6756 1/4 118 166 223 290 315 368 458 561 679 221 291 7.27
NL9CN 105H6856 1/3 138 194 259 335 364 423 526 643 778 250 334 8.35
SC10CNX 104H8065 1/3 126 179 245 325 355 420 531 660 809 274 362 10.29
SC12CNX 104H8265 3/8 178 250 331 426 462 540 678 846 1050 344 456 12.87
SC12CNX.2 104H8266 3/8 186 258 346 453 493 578 725 895 379 502 12.87
SC15CNX 104H8565 1/2 195 297 415 550 601 707 887 1093 1328 420 560 15.28
SC15CNX.2 104H8566 1/2 252 332 434 560 609 714 900 1120 445 610 15.28
SC18CNX 104H8865 5/8 219 341 480 640 700 824 1033 1272 1543 500 707 17.68
SC18CNX.2 104H8866 5/8 244 384 531 689 747 863 1057 1273 541 682 17.68
SC21CNX.2



Compressor ELECTROLUX, CUBIGEL ,GP12TB ,Hermetic piston ,ACC ,HMBP , moteur HP , 3/8 HP++, 1/2 hp– , 1PH , R134A , Pression 1.7 Bar , 220V

Type: Hermetic piston compressors Producer: ACCSeries: HMBP, cooling
Model: GP12TB
General data

Mbsm_dot_pro_private_PDF_GP12TB

 

Capillary : 0.42 , 0.32
180 psi
100mm
Refrigerant: R134a  
Discharge element: C-V  
Cooling: F  
Maximum ambient temperature [ºC]: 43  

Compressor’s data

     
Cylinder capacity [cm³]: 12,1  
Displacement [m³/h]: 2,1  
Weight [kg]: 11,2  
Oil charge [cm³]: 350  
Oil type: ISO VG 22 ESTER  

Engine’s data

     
Engine type: CSIR  
Power [KM]: 3/8  
Starting element: HST  
Power supply: 220V 50Hz  
Voltage range: 187-264  
Locked rotor current [A]: 13,5  
Running winding resistance (25ºC) [Ω]: 5,75  
Starting winding resistance (25ºC) [Ω]: 20,3  

Electrical data

     
Relays: 9660 A 138, MTRP 43  
Shielding element: MRT26AMK, T0181  
Starting capacitor volume [μF]:    

Connections

Type: Hermetic piston compressorsProducer: ACCSeries: HMBP
Model: GP12TB
General data

     
Refrigerant: R134a  
Discharge element: C-V  
Cooling: F  
Maximum ambient temperature [ºC]: 43  

Compressor’s data

     
Cylinder capacity [cm³]: 12,1  
Displacement [m³/h]: 2,1  
Weight [kg]: 11,2  
Oil charge [cm³]: 350  
Oil type: ISO VG 22 ESTER  

Engine’s data

     
Engine type: CSIR  
Power [KM]: 3/8  
Starting element: HST  
Power supply: 220V 50Hz  
Voltage range: 187-264  
Locked rotor current [A]: 13,5  
Running winding resistance (25ºC) [Ω]: 5,75  
Starting winding resistance (25ºC) [Ω]: 20,3  

Electrical data

     
Relays: 9660 A 138, MTRP 43  
Shielding element: MRT26AMK, T0181  
Starting capacitor volume [μF]:    

Connections

  milimeters inches  
Suction/service tube: 8,1    
Service/suction tube: 8,1    
Discharge tube: 6,5



The best way, to clean the capillary ,from oils, and repair Blockage, in cooling with Gaz R22

The best way to clean the capillary from oils and repair Blockage in cooling with Gaz R22

The best way to clean the capillary from oils and repair Blockage in cooling with Gaz R22
The best way to clean the capillary from oils and repair Blockage in cooling with Gaz R22

أفضل طريقة لتنظيف الشعيرات  من الزيوت وإصلاح الانسداد في التبريد باستخدام غاز R22

La meilleure façon de nettoyer les capillaires des huiles et de réparer les obstructions lors du refroidissement avec du gaz R22




QBH57C10GPX, 1/6HP ,RSIR, Reciprocating Fixed Speed, Compressors, R134a, LBP ,PANASONIC SMALL REFRIGERATOR

https://www.mbsm.pro/wp-content/uploads/2020/04/Mbsm_dot_pro_private_picture_qb66c13gpx5.pdf

An Khang Company est le fournisseur et le grossiste de Panasonic de petite capacité pour les réfrigérateurs, réfrigérateurs, congélateurs, etc. à l’échelle nationale. Avec la bonne qualité de modèle, le bon modèle, une capacité diversifiée adaptée à chacun.

>> Panasonic SFJ39C72RLW Refrigerator – 1 / 9HP – 220 ~ 240V – R134.

>> Panasonic SFJ48C87RLW Tornado – 1 / 7HP – 2240VAC – R134.

>> Panasonic refrigerator QBH57C10GPX – 1 / 6HP – 2240VAC – R134.

>> Panasonic refrigerators QBH66C13GPX – 1 / 5HP – 2240VAC – R134.

>> Panasonic refrigerators QBH73C16GPX – 1 / 5HP – 2240VAC – R134.

>> Panasonic refrigerator QBH86C19RPX – 1 / 4HP – 2240VAC – R134.

>> Panasonic refrigerator QB110C19GAW5–1 / 3HP – 220 ~ 240V – R134.




Installation de mitigeur de douche Jacousie encastré

Thank you for JOB PICTURES #Les artistes de plomberie et chauffage central




ZEL , Refrigeration ,Compressor ,Gml200a ,152w , 1/5 Hp ,220/240V/50Hz ,R134a

ZEL , Refrigeration ,Compressor ,Gml200a ,152w , 1/5 Hp ,220/240V/50Hz ,R134a
https://www.mbsm.pro/wp-content/uploads/2024/03/Mbsm_dot_pro_private_PDF_gml200a.pdf



HFC refrigerant , hydrofluorocarbons , is the third generation, of fluorinated refrigerants

HFC refrigerant (hydrofluorocarbons) is the third generation of fluorinated refrigerants. Recognized as Ozone Depleting Potential (ODP) and Global Warming Potential (GWP), they represent a greener alternative to CFC and HCFC. Refrigerants in this group are applicable to refrigeration plants and air conditioning units designed specifically for their use. In addition, they can serve as drop-in replacements for older CFCs and HCFCs.

The HFC group includes the following products:

R23
R32
R134a
R404A
R407A
R407C
R407F (PERFORMAX LT)
R410A
R417A (ISCEON MO59)
R422A (ISCEON MO79)
R422D (ISCEON MO29)
R423A (ISCEON 39TC)
R424A (RS-44)
R427A (Forane 427A)
R428A (RS-52)
R434A (RS-45)
R437A (ISCEON MO49Plus)
R438A (ISCEON MO99)
R442A (RS-50)
R449A (OPTEON XP40)
R507A
R508B (SUVA 95)
ISCEON MO89
R1234yf

HFC (مركبات الهيدروفلوروكربون) هي الجيل الثالث من المبردات المفلورة

. معترف بها على أنها إمكانات استنفاد الأوزون (ODP) وإمكانية الاحترار العالمي (GWP) ، فهي تمثل بديلاً أكثر خضرة لمركبات الكربون الكلورية فلورية ومركبات الكربون الهيدروكلورية فلورية. تنطبق المبردات في هذه المجموعة على محطات التبريد ووحدات تكييف الهواء المصممة خصيصًا لاستخدامها. بالإضافة إلى ذلك ، يمكن أن تكون بمثابة بدائل منسدلة لمركبات الكربون الكلورية فلورية ومركبات الكربون الهيدروكلورية فلورية القديمة.
تتضمن مجموعة HFC المنتجات التالية:
R23
R32
R134a
R404A
R407A
R407C
R407F (PERFORMAX LT)
R410A
R417A (ISCEON MO59)
R422A (ISCEON MO79)
R422D (ISCEON MO29)
R423A (ISCEON 39TC)
R424A (RS-44)
R427A (Forane 427A)
R428A (RS-52)
R434A (RS-45)
R437A (ISCEON MO49Plus)
R438A (ISCEON MO99)
R442A (RS-50)
R449A (OPTEON XP40)
R507A
R508B (SUVA 95)
ISCEON MO89
R1234yf

Le réfrigérant HFC (hydrofluorocarbures) est la troisième génération de réfrigérants fluorés. Reconnus comme potentiel d’appauvrissement de la couche d’ozone (ODP) et potentiel de réchauffement planétaire (GWP), ils représentent une alternative plus verte au CFC et au HCFC. Les réfrigérants de ce groupe sont applicables aux installations de réfrigération et aux unités de climatisation conçues spécifiquement pour leur utilisation. De plus, ils peuvent servir de remplacements directs pour les CFC et HCFC plus anciens.
Le groupe HFC comprend les produits suivants:
R23
R32
R134a
R404A
R407A
R407C
R407F (PERFORMAX LT)
R410A
R417A (ISCEON MO59)
R422A (ISCEON MO79)
R422D (ISCEON MO29)
R423A (ISCEON 39TC)
R424A (RS-44)
R427A (Forane 427A)
R428A (RS-52)
R434A (RS-45)
R437A (ISCEON MO49Plus)
R438A (ISCEON MO99)
R442A (RS-50)
R449A (OPTEON XP40)
R507A
R508B (SUVA 95)
ISCEON MO89
R1234yf