Mbsm.pro, Congélateur GN-bd(w)-370, Gean Electronique, Made in Chine, T classe, 370 L, Compressor, 1/4 Hp, R134A, 105 G, 1.3 A, 220 V, Freezer horizontal, Filtre 20 G, Capilaire 0.036, 2 M, Thermostat mecanique




Mbsm.pro, Compressor, Files, Pdf, Panasonic compressor, R134a, D-Series, Low Back Pressure

Mbsm.pro, Compressor, Files, Pdf, Panasonic compressor, R134a, D-Series, Low Back Pressure

 

QA77C17GAX5, 7.7, 220V 50Hz, RSIR, 176 w, 1/4 Hp, LBP, 186 w

 

 

d66c15Rax5, 6.6, 220V 50Hz, RSIR, 151 w, 1/5 Hp, LBP

Specification
 
Item Performance characteristics
Refrigerant R134a
Displacement (cm³) 6.6
Voltage (V) 220
Frequency (Hz) 50
Motor Type RSIR
Capacity@ASHRAE 151
COP@ASHRAE 1.22
Capacity@CECOMAF
COP@CECOMAF

 




Mbsm.pro, SWZ12, 000DK02D, 2eDM02000, Intercold, Freezer, swz1/170, 222 w, 230v, Compressor, 1/4 hp, R134a, 210 G, 290 L, Intercold horizontal freezers for frozen




Mbsm.pro, compressor, TS33vdec, air conditioner, Mitsubishi Hermetic, Refrigeration, Rotary Compressor, Model Ts33vdec, 1 Hp, 10098 btu/h, 945 w, R410A

PH 1 PH
Hp 1 Hp
Refrigerant: R410A
Displacement: 36 Cm3/Rev
Capacity: 10098BTU/H
Power Input: 945W



Mbsm.pro, Pdf, Is it useful to fill gas r22 in place of r410

هل ينفع تعبئة غاز 22 مكان ال410

Est-il utile de remplir de gaz 22 à la place de 410

Is it useful to fill gas 22 in place of 410

Simple information translated from the global site

www.MBSM.PRO

————————————————– —

Is it useful to fill gas 22 in place of 410

————————————————– —

The difference between gas 22 and gas 410 gas 410 is one of the types of gases that are environmentally friendly and does not harm the ozone layer and the lowest percentage of air pollution and its consumption is less than gas 22. Gas 22 is harmful to the environment and increases the pollution rate in the air and harms the ozone layer.. Banned by the Environmental Council

————————————————– ——

The difference in pressure

———— — ———————————– –

R22 = 4 Bar = 60 Pci

R410 A = 8 Bar = 117 Pci

————————————————

The difference in shipping method

————————————————

 Gas 22. Charging is carried out either in the bottle standing or inverted because it represents one gas and there is no problem in all cases . Charging will be done successfully if the scale is used, the ampere is adjusted and the cleaning is good.

 In the event of a major shortage in the air conditioner, the missing quantity can be added directly, taking into account the air discharge in the charging coil

 – Gas 410, the bottle is charged upside down only, with the balance, and with adjusting the amp and taking into account complete hygiene

In the event of a major shortage in the air conditioner, it must be completely unloaded, withdrawn, and fully recharged after repairing the leak with the use of a special charging coil for 410 gas.

————————————————– ——

Disadvantages of changing gas from 410 to 22

——————– —————— ———— —–

First, it is not correct to change the gas of 22 to 410, nor vice versa. In the event of a change, some things will happen .

A  lack of cold .

Large thermal leakage affecting the compressor due to the sudden change of pressures .

Damage to the compressor and deterioration of its life span .

 Damage to the start – up capacitor with the change of ampere .

Excessive consumption of electricity with the change in the sound of the air conditioner and its instability

 – If the inverter compressor means constant current, the damages will be greater until the internal evaporator fan is damaged, as the speeds will change and fluctuate .




Mbsm.pro, GKT141MBA, Compressor , LG, inverter, BDC, DC compressor, 3 PH, 2.5 HP, 18000 Btu/h, R410A

CAPACITY

  • Cooling
    3690~18000~18500 (Btu/h)

ELEC. RATING

  • Power Supply
    1Φ, 220~240V, 50Hz
    Power Supply Cable
    3*1.5 (No.*㎟)
  • Power and Transmission Cable
    4*1.5 (No.*㎟)
    Power Input (Cooling)
    1600 W
  • Running Current (Cooling)
    7.7 A
    Starting Current (Cooling)
    7.7 A
  • EER
    3.30 W/W
    Circuit Breaker
    20 A

AIR FLOW RATE

  • Indoor,Max
    17.8 (629) ㎥/min(CFM)
    Outdoor,Max
    38 (1342) ㎥/min(CFM)

SOUND LEVEL

  • Indoor,H/M/L/SL
    42/40/35/29 dB(A)+1
    Outdoor,Max
    51 dB(A)+1

FAN(INDOOR)

  • Type
    Cross Flow Fan
    Motor Type
    BLDC
  • Motor Output
    30 W

FAN(OUTDOOR)

  • Type
    Propeller
    Motor Type
    BLDC
  • Motor Output
    43 W

PIPING CONNECTIONS

  • Liquid Side
    6.35(1/4) mm(in)
    Gas Side
    12.7(1/2) mm(in)

COMPRESSOR

  • Type
    Twin Rotary
    Model
    GKT141MBA
  • Motor Type
    Brushless DC Motor
    Oil Type
    FVC68D
  • Oil Charge
    470 cc

OPERATION RANGE

  • Cooling (Indoor)
    18 ~ 32 (64.4 ~ 89.6) ℃(℉)
    Cooling (Outdoor)
    18 ~ 48 (64.4 ~ 118.4) ℃(℉)

DIMENSIONS

  • Indoor (W*H*D)
    1030*325*250 mm
    Pack Indoor (W*H*D)
    1095*302*394 mm
  • Outdoor (W*H*D)
    770*545*288 mm
    Pack Outdoor (W*H*D)
    905*573*378 mm

NET WEIGHT

  • Indoor
    12.4(27.3) kg(lbs)
    Outdoor
    32.4(71.4) kg(lbs)

SET WEIGHT

  • Indoor
    13.4(29.5) kg(lbs)
    Outdoor
    34.5(76.1) kg(lbs)



Mbsm.pro, air conditioner, HBM-18000c, Hyunday, 18000 btu/h, 1.5 ton, 2 hp++, Cooling only, t1




Mbsm.pro, Compressor, EG70HLR, Embraco, Refrigerator, 1/4 hp, Lbp, R134, Eg 70 Hlr

Mbsm.pro, Compressor, EG70HLR, Embraco, Refrigerator, 1/4 hp, Lbp, R134, Eg 70 Hlr

Compressore EMBRACO
Modello EG70HLR
Altezza (mm)
Gas R134a
Tensione 220-240 V 50-60 Hz
Applicazione LBP (Low Back Pressure)
Test Condition ASHRAE LBP 32
Cilindrata 6,76 c.c.
Motore RSIR-CSIR
Potenza (HP) 1/4
Cap. Frigor. Watt 192/228
Cap. Frigor. Kcal 165/196
Cap. Frigor. Btu/h 655/777
COP (W/W) 1,39/1,45
Watt assorbiti (W)
Dispositivo di Avv. Relay
Condensatore 72-88 MF
Tipo Raffreddamento
Imballo (Pcs/Pallet)



Mbsm.pro, Compressor Lg, 26000 btu/h, QP442PBA, LG, AC Rotary Compressor, Rotary Scroll Compressor, 220-240V 50HZ, 2 ton, 3 Hp++, 1 PH, Cappilary 070 Two pieces, 45 cm long

26000bu QP442PBA LG AC Rotary Compressor , Rotary Scroll Compressor 220-240V 50HZProduct DescriptionBrief history of Tele

1991 Tele Group established
1997 Authorized to be the sole agent of Panasonic rotary compressor in China
1999 Authorized to be general agent of Daikin scroll compressor
2000 Authorized to be the agent of LG rotary compressor
2003 Authorized to be general agent of Daikin Refrigerant in China Agent of Panasonic Auto A/C Compressor
2010 Authorized to be Danfoss Agent Performance Compressor

Brand: LG
Specfication:

Model Voltage Cooling Capacity (W) Cooling Capacity(PTO) Exodus (c/review) power input (w) COP (w/s)
QJ208HCA 220 V 50 Hz 3546 12100 20.8 1110 3.19
QK222JBA 200-220V 50Hz 3810 12750 22.2 1280 2.97
QJ306PCB 220-240V 50Hz 5364 18300 30.6 1803 2.93
QJ330PAA 220-240V 51Hz 5832 19900 33 1877 3.11
QP376PBA 220-240V 52Hz 6594 22500 37.6 2143 3.08
QP407PAA 220-240V 53Hz 7063 24100 40.7 2317 3.05
QP442PBA 220-240V 54Hz 7620 26000 44.2 2549



Mbsm.pro, air conditioner, GiBson, GS18K11BCHI, 18000 btu, 15 A, 2900 w, Cooling, Heating, r410a, 1400 G, 220v50hz, T1