Technical Data of Air-cooled medium & High Temperature Unit
Condensing Unit model |
CompressormodelCompressormodel _ |
Power Supply |
Cooling capacity W |
Power consumption KW |
Air Condenser Air-cooled |
By tube size |
Heat exchange area m 2 |
Total air volume m 3 /h |
Blade diameter mm |
Motor power W |
number of poles |
back gas |
discharge |
LH34/2HC2.2FH |
2HC-2.2 |
380V 3Ph 50Hz |
3380 |
1.62 |
18 |
3000 |
400 |
300 |
4 |
16 |
10 |
LH34/2GC2.2FH |
2GC-2.2 |
3990 |
1.87 |
18 |
3000 |
400 |
300 |
4 |
16 |
10 |
LH44/2FC3.2FH |
2FC-3.2 |
4820 |
2.31 |
25 |
3000 |
400 |
300 |
4 |
16 |
12 |
LH44/2EC3.2FH |
2EC-3.2 |
5670 |
2.61 |
25 |
3000 |
400 |
300 |
4 |
22 |
12 |
LH64/2CC4.2FH |
2CC-4.2 |
8350 |
3.67 |
35 |
3000 |
400 |
300 |
4 |
22 |
12 |
LH84/4FC5.2FH |
4FC-5.2 |
9640 |
4.12 |
55 |
5000 |
450 |
370 |
4 |
22 |
12 |
LH84/4EC6.2FH |
4EC-6.2 |
11850 |
5.12 |
55 |
5000 |
450 |
370 |
4 |
28 |
12 |
LH94/4DC7.2FH |
4DC-7.2 |
14480 |
6.14
|
70 |
6000 |
400 |
2×300 |
4 |
28 |
16 |
LH104-1/4CC9.2FH |
4CC-9.2 |
17500 |
7.5 |
80 |
6000 |
400 |
2×300 |
4 |
28 |
16 |
LH104-2/4VCS10.2FH |
4VCS-10.2 |
19190 |
7.43 |
95 |
10000 |
450 |
2×370 |
4 |
28 |
16 |
LH114/4NCS12.2FH |
4NCS-12.2 |
23150 |
9.13 |
110 |
10000 |
450 |
2×370 |
4 |
35 |
16 |
LH135-1/4PCS15.2FH |
4PCS-15.2 |
27700 |
10.45 |
130 |
14000 |
500 |
2×550 |
4 |
35 |
22 |
LH135-2/4G20.0FH |
4G-20.2 |
32300 |
13.08 |
155 |
14000 |
500 |
2×550 |
4 |
42 |
22 |
LH135-3/4H25.2FH |
4H-25.2 |
42250 |
16.09 |
180 |
14000 |
550 |
2×550 |
4 |
54 |
22 |
LH240/4G30.2FH |
4G-30.2 |
48500 |
19.02 |
240 |
20000 |
450 |
4×370 |
4 |
54 |
22 |
FV300/6H35.2FH |
6H-35.2 |
63400 |
24.20 |
300 |
27000 |
600 |
3×550 |
6 |
54 |
28 |
FV350/6G40.2FH |
6G-40.2 |
72800 |
28.50 |
350 |
36000 |
650 |
3×550 |
6 |
54 |
28 |
FV410/6F50.2FH |
6F-50.2 |
86300 |
35.40 |
410 |
45000 |
700 |
3×550 |
8 |
54 |
35 |
Note: Working conditions for vaporizing temperature at -5℃ condesing temperature at 50℃, and used by R22 refriger ant.
Technical Data of Bitzer Air-cooled units
Air-cooled medium & High Temperature Unit
Condensing Unit model |
Compressor model |
Overall size(mm) |
Installation size |
Mounting Aperture |
long A |
wide B |
High C |
long F |
Wide E |
LH34/2HC2.2FH |
2HC-2.2 |
600 |
650 |
580 |
560 |
400 |
4-Φ13 |
LH34/2GC2.2FH |
2GC-2.2 |
600 |
650 |
580 |
560 |
400 |
4-Φ13 |
LH44/2FC3.2FH |
2FC-3.2 |
680 |
680 |
600 |
640 |
400 |
4-Φ13 |
LH44/2EC3.2FH |
2EC-3.2 |
680 |
680 |
600 |
640 |
400 |
4-Φ17 |
LH64/2CC4.2FH |
2CC-4.2 |
780 |
680 |
700 |
740 |
400 |
4-Φ17 |
LH84/4FC5.2FH |
4FC-5.2 |
880 |
760 |
800 |
840 |
480 |
4-Φ17 |
LH84/4EC6.2FH |
4EC-6.2 |
880 |
760 |
800 |
840 |
480 |
4-Φ17 |
LH94/4DC7.2FH |
4DC-7.2 |
1130 |
760 |
700 |
1090 |
480 |
4-Φ17 |
LH104-1/4CC9.2FH |
4CC-9.2 |
1130 |
760 |
700 |
1090 |
480 |
4-Φ17 |
LH104-2/4VCS10.2FH |
4VCS-10.2 |
1130 |
760 |
800 |
1090 |
480 |
4-Φ17 |
LH114/4NCS12.2FH |
4TCS-12.2 |
1340 |
860 |
760 |
1300 |
580 |
4-Φ17 |
LH135-1/4PCS15.2FH |
4PCS-15.2 |
1490 |
860 |
960 |
1450 |
580 |
4-Φ17 |
LH135-2/4G20.0FH |
4G-20.2 |
1490 |
860 |
960 |
150 |
580 |
4-Φ20 |
LH135-3/4H25.2FH |
4H-25.2 |
1590 |
860 |
960 |
1550 |
580 |
4-Φ20 |
LH240/4G30.2FH |
4G-30.2 |
1590 |
860 |
1360 |
1550 |
580 |
4-Φ20 |
FV300/6H35.2FH |
6H-35.2 |
1040 |
360 |
800 |
800 |
320 |
4-Φ20 |
FV350/6G40.2FH |
6G-40.2 |
1190 |
360 |
860 |
950 |
320 |
4-Φ20 |
FV410/6F50.2FH |
6F-50.2 |
1490 |
360 |
860 |
1250 |
320 |
4-Φ20 |
Note: We reserve the right to modify the above overall and installation sizes without prior notice.
Technical Data of Bitzer Air-cooled units
Technical Data of Air-cooled medium & low Temperature Unit
condensing Unit model |
Compressor model |
Power Supply |
Cooling capacity W |
Power consumption KW |
Condenser Air-cooled |
By tube size |
Heat exchange area m 2 |
Total air volume m 3 /h |
Blade diameter mm |
Power W |
number of poles |
back gas |
discharge |
LH34/2FC2.2FM |
2FC-2.2 |
380V 3Ph 50Hz |
2700 |
1.73 |
18 |
3000 |
400 |
300 |
4 |
16 |
10 |
LH44/2EC2.2FM |
2EC-2.2 |
3150 |
2.09 |
25 |
3000 |
400 |
300 |
4 |
22 |
12 |
LH44/2CC3.2FM |
2CC-3.2 |
4450 |
2.79 |
25 |
3000 |
400 |
300 |
4 |
22 |
12 |
LH64/4FC3.2FM |
4FC-3.2 |
4960 |
3.42 |
35 |
3000 |
400 |
300 |
4 |
22 |
12 |
LH64/4EC4.2FM |
4EC-4.2 |
6160 |
4.01 |
35 |
3000 |
400 |
300 |
4 |
22 |
12 |
LH74/4DC5.2FM |
4DC-5.2 |
7280 |
4.67 |
42 |
5000 |
450 |
370 |
4 |
28 |
12 |
LH84/4CC6.2FM |
4CC-6.2 |
8390 |
5.67 |
55 |
5000 |
450 |
370 |
4 |
28 |
12 |
LH94/4TcS8.2FM |
4TCS-8.2 |
11880 |
6.90 |
70 |
6000 |
400 |
2×300 |
4 |
35 |
16 |
LH104-1/4PCS10.2FM |
4PCS10.2 |
13800 |
7.95 |
80 |
6000 |
400 |
2×300 |
4 |
35 |
16 |
LH104-2/4NCS12.2FM |
4NCS12.2 |
16150 |
9.27 |
95 |
10000 |
450 |
2×370 |
4 |
35 |
16 |
LH114/4H15.2FM |
4H15.2 |
21100 |
12.45 |
110 |
10000 |
450 |
2×370 |
4 |
42 |
22 |
LH135-1/4G20.2FM |
4G20.2 |
24450 |
14.88 |
130 |
14000 |
500 |
2×550 |
4 |
54 |
22 |
LH135-2/6J22.2FM |
6J22.2 |
27350 |
16.13 |
155 |
14000 |
500 |
2×550 |
4 |
54 |
22 |
LH135-3/6H25.2FM |
6H25.2 |
31700 |
18.70 |
180 |
14000 |
500 |
2×550 |
4 |
54 |
22 |
LH240/6G30.2FM |
6G30.2 |
36700 |
22.30 |
240 |
20000 |
450 |
4×370 |
4 |
54 |
22 |
FNV300/6F40.2FM |
6F40.2 |
44100 |
27.10 |
300 |
27000 |
600 |
3×550 |
6 |
54 |
28 |
Working conditions for vaporizing temperature at -20℃ condesing temperature at 50℃, and used by R22 refriger ant CIC necessary when the vaporizing temperature is low.
Technical Data of Bitzer Air-cooled units
Installation size of Air-cooled medium & Low Temperature Unit
Condensing Unit model |
Compressor model |
Overall size(mm) |
Installation size |
Mounting Aperture |
long A |
wide B |
High C |
long F |
Wide E |
LH34/2FC2.2FM |
2FC-2.2 |
600 |
650 |
580 |
560 |
400 |
4-Φ13 |
LH44/2EC2.2FM |
2EC-2.2 |
680 |
680 |
600 |
640 |
400 |
4-Φ13 |
LH44/2CC3.2FM |
2CC-3.2 |
680 |
680 |
600 |
640 |
400 |
4-Φ17 |
LH64/4FC3.2FM |
4FC-3.2 |
780 |
680 |
700 |
740 |
400 |
4-Φ17 |
LH64/4EC4.2FM |
4EC-4.2 |
780 |
680 |
700 |
740 |
400 |
4-Φ17 |
LH74/4DC5.2FM |
4DC-5.2 |
880 |
760 |
800 |
840 |
480 |
4-Φ17 |
LH84/4CC6.2FM |
4CC-6.2 |
880 |
760 |
800 |
840 |
480 |
4-Φ17 |
LH94/4TCS8.2FM |
4TCS-8.2 |
1130 |
760 |
700 |
1090 |
480 |
4-Φ17 |
LH104-1/4PCS10.2FM |
4PCS10.2 |
1130 |
760 |
700 |
1090 |
480 |
4-Φ17 |
LH104-2/4NCS12.2FM |
4NCS12.2 |
1130 |
760 |
800 |
1090 |
480 |
4-Φ17 |
LH114/4H15.2FM |
4H15.2 |
1340 |
860 |
760 |
1300 |
580 |
4-Φ17 |
LH135-1/4G20.2FM |
4G20.2 |
1490 |
860 |
960 |
1450 |
580 |
4-Φ17 |
LH135-2/6J22.2FM |
6J22.2 |
1490 |
860 |
960 |
1450 |
580 |
4-Φ20 |
LH135-3/6H25.2FM |
6H25.2 |
1590 |
860 |
960 |
1550 |
580 |
4-Φ20 |
LH240/6G30.2FM |
6G30.2 |
1590 |
860 |
1360 |
1550 |
580 |
4-Φ20 |
FNV300/6F40.2FM |
6F40.2 |
1190 |
360 |
860 |
950 |
320 |
4-Φ20 |
Note: We reserve the right to modify the above overall and installation sizes without prior notice.
Technical Data of Bitzer Water-cooled units
Technical Data of Water-cooled medium & High Temperature Unit
Unit Type |
Compressor Model |
Power KW |
Cooling capacity W |
Return air (mm) |
Liquid supply (mm) |
water pipe G |
Water supply (m 3 /h) |
WN4/2FC3.2WH |
2FC3.2 |
2.00 |
5590 |
Φ16 |
Φ12 |
3/2″ |
2 |
WN5/2CC4.2WH |
2CC4.2 |
3.31 |
9890 |
Φ22 |
Φ16 |
3/2″ |
2.5 |
WH8/4FC5.2WH |
4FC5.2 |
3.66 |
11230 |
Φ22 |
Φ16 |
3/2″ |
3.3 |
WH8/4EC6.2WH |
4EC6.2 |
4.56 |
13860 |
Φ22 |
Φ16 |
3/2″ |
4.0 |
WH10/4DC7.2WH |
4DC7.2 |
5.40 |
16830 |
Φ28 |
Φ19 |
3/2″ |
4.8 |
WH10/4CC9.2WH |
4CC9.2 |
6.64 |
20250 |
Φ28 |
Φ19 |
2″ |
6.5 |
WH15/4VCS10.2WH |
4VCS10.2 |
6.61 |
22250 |
Φ28 |
Φ19 |
2″ |
6.9 |
WH15/4TCS12.2WH |
4TCS12.2 |
8.09 |
26800 |
Φ35 |
Φ19 |
2″ |
8.0 |
WH15/4PCS15.2WH |
4PCS15.2 |
9.35 |
31950 |
Φ42 |
Φ22 |
2″ |
9.2 |
WH20/4NCS20.2WH |
4NCS20.2 |
11.34 |
37000 |
Φ42 |
Φ22 |
2″ |
12.0 |
WH25/4J22.2WH |
4J22.2 |
12.25 |
40900 |
Φ42 |
Φ22 |
2″ |
13.5 |
WH30/4H25.2WH |
4H25.2 |
14.20 |
47400 |
Φ54 |
Φ22 |
5/2″ |
14.0 |
WH35/4G30.2WH |
4G30.2 |
16.76 |
54400 |
Φ54 |
Φ22 |
5/2″ |
16.5 |
WH40/6H35.2WH |
6H35.2 |
21.30 |
71200 |
Φ54 |
Φ28 |
5/2″ |
21.8 |
WH45/6G40.2WH |
6G40.2 |
25.20 |
81600 |
Φ54 |
Φ28 |
5/2″ |
24.5 |
WH50/6F50.2WH |
6F50.2 |
31.4 |
96500 |
Φ54 |
Φ28 |
3″ |
29.0 |
Note: Working conditions for vaporizing temperature at -5℃ condesing temperature at 40℃, and used by R22 refriger ant. It working for 380 50Hz
Technical Data of Bitzer Water-cooled units
Installation size of water-cooled Medium & High Temperature Unit
Unit Model |
Compressor Model |
Overall size(mm) |
Installation size (mm) Installation size |
Mounting aperture mm |
long A |
wide B |
High H |
long E |
wide F |
WN4/2FC3.2WH |
2FC3.2 |
1010 |
350 |
720 |
780 |
300 |
Φ18 |
WN5/2CC4.2WH |
2CC4.2 |
1010 |
350 |
720 |
780 |
300 |
Φ18 |
WN8/4FC5.2WH |
4FC5.2 |
1080 |
350 |
760 |
850 |
300 |
Φ18 |
WN8/4EC6.2WH |
4EC6.2 |
1080 |
350 |
760 |
850 |
300 |
Φ18 |
WN10/4DC7.2WH |
4DC7.2 |
1120 |
350 |
800 |
890 |
300 |
Φ18 |
WN10/4CC9.2WH |
4CC9.2 |
1120 |
350 |
800 |
890 |
300 |
Φ18 |
WN15/4VCS10.2WH |
4VCS10.2 |
1220 |
400 |
850 |
990 |
350 |
Φ18 |
WN15/4NCS12.2WH |
4NCS12.2 |
1220 |
400 |
850 |
990 |
350 |
Φ18 |
WN15/4PCS15.2WH |
4PCS15.2 |
1220 |
400 |
850 |
990 |
350 |
Φ18 |
WN20/4NCS20.2WH |
4NCS20.2 |
1220 |
400 |
850 |
990 |
350 |
Φ18 |
WN25/4J22.2WH |
4J22.2 |
1320 |
400 |
950 |
1080 |
350 |
Φ18 |
WN30/4H25.2WH |
4H25.2 |
1620 |
400 |
950 |
1400 |
350 |
Φ18 |
WN35/4G30.2WH |
4G30.2 |
1620 |
400 |
950 |
1400 |
350 |
Φ18 |
WN40/6H35.2WH |
6H35.2 |
1620 |
400 |
950 |
1400 |
350 |
Φ18 |
WN45/6G40.2WH |
6G40.2 |
1900 |
400 |
1000 |
1680 |
350 |
Φ18 |
WN50/6F50.2WH |
6F50.2 |
1900 |
400 |
1000 |
1680 |
350 |
Φ18 |
Note: We reserve the right to modify the above overall and installation sizes without prior notice.
Technical Data of Bitzer Water-cooled units
Technical Data of Work-cooled medium & low Temperature Unit
Unit Model |
Compressor Model |
power |
Cooling capacity |
back gas |
liquid supply |
water pipe |
Water supply |
KW |
IN |
mm |
mm |
G |
m 3 /h |
WN04/2CC3.2WM |
2CC-3.2 |
2.6 |
5500 |
22 |
12 |
1-1/2 |
1.5 |
WN05 / 4EC4.2WM |
4EC-4.2 |
3.7 |
7550 |
22 |
16 |
1-1/2 |
2.5 |
WN08/4DC5.2WM |
4DC-5.2 |
4.4 |
8830 |
28 |
16 |
1-1/2 |
3.0 |
WN08 / 4CC6.2WM |
4CC-6.2 |
5.2 |
10230 |
28 |
16 |
1/1/2 |
3.5 |
WN10/4TCS8.2WM |
4TCS-8.2 |
6.4 |
14150 |
35 |
22 |
1-1/2 |
4.5 |
WN10/4PCS10.2WM |
4PCS-10.2 |
7.4 |
16390 |
35 |
22 |
2 |
5.5 |
WN15 / 4NCS12.2WM |
4VCS-12.2 |
8.7 |
19160 |
35 |
22 |
2 |
6.0 |
WN20 / 4H15.2WM |
4H-15.2 |
11.2 |
24450 |
42 |
25 |
2 |
7.8 |
WN25/4G20.2Wm |
4G-20.2 |
13.1 |
28200 |
54 |
28 |
2 |
9.0 |
WN30/6H25.2WM |
6H-25.2 |
16.8 |
36700 |
54 |
28 |
2 |
12.0 |
WN35/6G30.2WM |
6G-30.2 |
19.6 |
42300 |
54 |
28 |
2-1/2 |
14.5 |
WN45 / 6F40.2WM |
6F-40.2 |
24.3 |
50500 |
54 |
28 |
2-1/2 |
16.8 |
Working conditions for vaporizing temperature at -20℃ condesing temperature at 50℃, and used by R22 refriger ant CIC necessary when the vaporizing temperature is low.
Technical Data of Bitzer Water-cooled units
Installation size of Water cooled Medium & Low Temperature Unit
Unit Model |
Compressor Model |
Overall size(mm) |
Installation size (mm) Installation size |
Mounting Aperture |
long A |
wide B |
High H |
long E |
wide F |
WN04/2CC3.2WM |
2CC-3.2 |
1010 |
350 |
720 |
780 |
300 |
Φ18 |
WN05 / 4EC4.2WM |
4EC-4.2 |
1010 |
350 |
720 |
780 |
300 |
Φ18 |
WN08/4DC5.2WM |
4DC-5.2 |
1080 |
350 |
760 |
850 |
300 |
Φ18 |
WN08 / 4CC6.2WM |
4CC-6.2 |
1080 |
350 |
760 |
850 |
300 |
Φ18 |
WN10/4TCS8.2WM |
4TCS-8.2 |
1120 |
350 |
800 |
890 |
300 |
Φ18 |
WN10/4PCS10.2WM |
4PCS-10.2 |
1120 |
350 |
800 |
890 |
300 |
Φ18 |
WN15 / 4NCS12.2WM |
4VCS-12.2 |
1220 |
400 |
850 |
990 |
350 |
Φ18 |
WN20 / 4H15.2WM |
4H-15.2 |
1220 |
400 |
850 |
990 |
350 |
Φ18 |
WN25/4G20.2WM |
4G-20.2 |
1320 |
400 |
950 |
1080 |
350 |
Φ18 |
WN30/6H25.2WM |
6H-25.2 |
1620 |
400 |
950 |
1400 |
350 |
Φ18 |
WN35/6G30.2WM |
6G-30.2 |
1620 |
400 |
950 |
1400 |
350 |
Φ18 |
WN45 / 6F40.2WM |
6F-40.2 |
1900 |
400 |
1000 |
1680 |
350 |
Φ18 |
Note: We reserve the right to modify the above overall and installation sizes without prior notice.
Main Technical Data of Copeland C series semi-hermatic units
Main Technical Data of Air-cooled semi-hermatic units
Unit model |
compressor |
Cooling capacity R22 (KW) |
power supply |
Reservoir (L) |
Overall size |
installation size |
Take over tube(mm) |
model _ |
power |
mobile phone |
KW |
long A |
wide B |
High H |
long a |
wide b |
inhale |
liquid supply |
FNH28/CA0300AH |
CA-0300 |
3 |
2.2 |
5.35 |
3Ph 380V 50Hz _ _
|
7.5 |
720 |
650 |
600 |
680 |
400 |
19 |
10 |
FNH34/CA0400AH |
CA-0400 |
4 |
3.0 |
6.94 |
7.5 |
770 |
650 |
655 |
730 |
400 |
25 |
12 |
FNH41/CA0500AH |
CA-0500 |
5 |
3.7 |
7.6 |
10 |
820 |
650 |
755 |
770 |
400 |
25 |
12 |
FNH55/cA0800AH |
CA-0800 |
8 |
5.5 |
11.62 |
15 |
940 |
700 |
860 |
890 |
420 |
32 |
16 |
FNH80/cA1000AH |
CA-1000 |
10 |
7.5 |
17.63 |
20 |
1220 |
850 |
960 |
1170 |
570 |
32 |
16 |
FNH100/CA1500AH |
CA-1500 |
15 |
10.5 |
21.4 |
25 |
1440 |
850 |
960 |
1390 |
580 |
38 |
19 |
Note: working conditions for vaporizing temperature at -15℃ condesing temperature at 30℃, and used by R22 refriger ant
Main Technical Data of Copeland C series semi-hermatic units
Main Technical Data of water-cooled semi-hermatic units
Unit model
|
compressor |
Cooling capacity (KW) |
power supply |
Overall size |
installation size |
Take over tube(mm) |
In and out water pipes |
model _ |
power |
mobile phone |
KW |
long A |
wide B |
High H |
long a |
wide b |
inhale |
liquid supply |
G |
WN03/C0300WL |
C-0300 |
3 |
2.2 |
5.35 |
3Ph 380V 50Hz
|
810 |
300 |
650 |
600 |
250 |
19 |
10 |
G1 |
WN04/CA0400WL |
CA-0400 |
4 |
3.0 |
6.74 |
1010 |
350 |
720 |
780 |
300 |
25 |
12 |
G3 / 2 |
WN05/C0500WL |
C-0500 |
5 |
3.7 |
7.08 |
1010 |
350 |
720 |
780 |
300 |
25 |
12 |
G3 / 2 |
WN08 / CA0800WL |
CA-0800 |
8 |
5.5 |
9.76 |
1080 |
350 |
720 |
850 |
300 |
32 |
16 |
G3 / 2 |
WN10/C1000WL |
C-1000 |
10 |
7.5 |
14.25 |
1120 |
350 |
800 |
890 |
300 |
32 |
16 |
G3 / 2 |
WN15/C1500WL |
C-1500 |
15 |
10.5 |
20.4 |
1220 |
400 |
800 |
990 |
350 |
38 |
19 |
G2 |