Mbsm.pro, Air Conditioner, Capacities, and Run Capacitors, with +/- 5% Variations, With fun

Air Conditioner Capacities and Run Capacitors with +/- 5% Variations for Technicians

This comprehensive table presents the recommended run capacitor capacities for various air conditioner cooling capacities, catering specifically to technicians and HVAC professionals. It’s crucial to note that these values are estimates, and the actual run capacitor capacity may vary depending on the specific brand, model, and specifications of your air conditioner. Always consult the air conditioner’s owner’s manual to determine the exact run capacitor capacity required. Using an incorrect run capacitor can damage your air conditioner and pose safety risks.

Key:

  • BTU/h: British Thermal Units per hour (measure of cooling capacity)
  • µF: Microfarad (unit of capacitance)
Air Conditioner Cooling Capacity (BTU/h) Recommended Run Capacitor (µF) +5% Variation (µF) -5% Variation (µF) External Fan Run Capacitor (µF) -5% of External Fan Run Capacitor (µF) +5% of External Fan Run Capacitor (µF)
9,000 30 31.5 28.5 1.5 1.35 1.65
12,000 35 36.75 33.25 2.0 1.8 2.2
18,000 45 47.25 42.75 2.5 2.25 2.75
24,000 55 57.75 52.25 3.0 2.7 3.3
30,000 65 68.25 61.75 3.5 3.15 3.85
36,000 80 84 76 4.0 3.6 4.4

Understanding External Fan Run Capacitor:

The values in this column are provided for informational purposes only and should not be used as a direct replacement for the recommended run capacitor capacity. Technicians should exercise caution when selecting a run capacitor that is slightly larger or smaller than the recommended value. In such cases, it’s highly recommended to consult with a qualified HVAC specialist for specific guidance based on the particular air conditioner unit.

Additional Considerations for Technicians:

  • The size of the run capacitor is typically determined by the motor power of the air conditioner.
  • A run capacitor that is too small can prevent the motor from starting properly, leading to potential malfunctions.
  • Conversely, a run capacitor that is too large can overheat and cause damage to the motor.

Always exercise caution and consult a qualified HVAC professional if you have any doubts about the appropriate run capacitor for a specific air conditioner.

Technical Explanations and Guidance:

  1. Capacitor Tolerance:The +/- 5% variations in the table represent the tolerance range for the recommended run capacitor values. This means that the actual capacitance of the selected capacitor may be slightly higher or lower than the recommended value within this range. However, it’s crucial to stay within this tolerance range to ensure optimal performance and prevent potential issues.
  2. Selecting the Right Run Capacitor:When selecting a run capacitor for an air conditioner, it’s essential to consider the following factors:

    • Air Conditioner Cooling Capacity (BTU/h): Match the run capacitor capacity to the corresponding BTU/h rating of the air conditioner.
    • Motor Power: Ensure the run capacitor’s voltage rating matches the motor’s voltage requirement.
    • Physical Size: Verify that the run capacitor’s physical dimensions fit the available space within the air conditioner unit.
    • Brand Reputation: Opt for run capacitors from reputable brands known for their reliability and quality.

  3. Replacing Run Capacitors:Replacing a run capacitor should be done with caution and proper electrical safety procedures. Here’s a general guideline:

    • Disconnect Power: Before attempting any work, ensure the air conditioner is completely disconnected from the power source.
    • Discharge Existing Capacitor: Use an appropriate discharging tool to safely discharge the existing capacitor.
    • Identify Replacement Capacitor: Carefully remove the old capacitor and note its specifications (capacitance, voltage, terminal type). Select a new capacitor with matching specifications.
    • Install New Capacitor: Install the new capacitor, ensuring proper polarity and terminal connections.
    • Reconnect Power: Once the new capacitor is securely installed, reconnect the power supply to the air conditioner.




Mbsm.pro, compressor, Gree, Air conditioner, OXSH-F375E090, OXSH-F375, 22100 BTU, 37.50 cm3, 6477 w, capacitor 60 uf, 1.8 ton, 2.8 hp, 220 v, 1ph, r22




Mbsm.pro, air conditioner, 42khrt24, 24000 btu, 2 t, 3 hp, r22

42khrt24 appears to be the indoor unit model number for a Carrier air conditioner system. Here’s what I can tell you about it:

Specifications:

  • Cooling capacity: 23,000 BTU/hr
  • Dehumidification rate: 2.6 liters/hour
  • Airflow rate: 560/590/620 cubic meters per hour (low/medium/high)
  • Sound pressure level: 42/45/48 dB(A) (low/medium/high)
  • Dimensions: 1030 x 313 x 221 mm (width x height x depth)
  • Weight: 17 kg

Features:

  • Split-type air conditioner
  • Carrier Optimax series
  • Wall-mounted unit
  • Remote control
  • Sleep mode
  • Turbo mode
  • Self-diagnosis function
  • Refrigerant type: R22

Additional information:

  • 42khrt24 is typically paired with the outdoor unit model 38khrt24.
  • This air conditioner system is designed for cooling rooms up to approximately 70 square meters (750 square feet).
  • It is available in some regions, but not all.



Mbsm.pro, Toshiba, R22, pH170g1c-4dzde, Air Conditioner, Compressor, 1 ton, 12000 btu, 1.5 hp

SPECIFICATIONS FOR PH170G1C-3FTDU1
Products Details
Models: PH170G1C-3FTDU1
Type
Hermetic
Power
Phase
1
Horse Power
HP
1.5
Main performance parameters
Input Power
W
208-230/1/60
REFRIGRANT
R22
SIZE
54.0/35.0
Physcial parameters
Height
MM
285
Weight
KG
160
Q’ty / Pallet
PIECE
18

• Température d’évaporation : 7,2 °/45 °F
• Temp. de condensation : 54,4 °/ 130 °F
• Temp. de gaz de retour : 35,0 °/ 95 °F
• Temp. ambiante : 35,0 °/ 95 °
F 115 °F
• Table de conversion : Kcal/hx 1,163 = W W x 3,412 = Btu/h

 

Mbsm_dot_pro_private_PDF_ph170g1c




Mbsm.pro, air conditioner, mediterranean , CON12HR3, Split type air conditioner, 12000 btu, r22, 850 g, 1350 w, 6 A,




Mbsm.pro, Air conditioner, Compressor, 24000 btu, 3RV416H2AAF, R-22, 220-240V, Sanyo

Mbsm.pro, Air conditioner, Compressor, 24000 btu, 3RV416H2AAF, R-22, 220-240V, Sanyo

Mbsm.pro, Air conditioner, Compressor, 24000 btu, 3RV416H2AAF, R-22, 220-240V, Sanyo



Mbsm.pro, Air conditioner, AUX ASW-H09A4, 9000 btu

Air conditioner AUX ASW-H09A4/FAR1 (internal + external)
You can use air conditioning in an area of up to 25-35 m². In the mode, the capacity of the air conditioner is 9000
BTU / hour, and in the cooling mode – 8800 BTU / hour. The air conditioner has an ionization function, has a
display and a timer. It also has the function of automatic reset and self-cleaning.
Technical Specifications:
• Brand: AUX
• Model: ASW-H09A4/FAR1
• Type: wall split system
• Recommended area: up to 25-35 m²
• Energy efficiency class: A
• Power heating mode: 9000 BTU / h
• Power cooling mode: 8800 BTU / h
• Power consumption during heating: 2.55 kW
• Power consumption during cooling: 2.65 kW
• Air flow: 800 m³ / h
• Froyn Type: R410
Additional features:
• Ionization
• Timer
• Display
• Cleanse yourself
• Automatic reloading
Physical characteristics:
• Noise level noise level: 42 dB
• Noise block noise level: 58 dB
• Internal block size: 800 × 300 × 198 mm
• External block size: 720 × 540 × 260 mm
• Internal block color: white




air conditioner, LG, Kf-50gw, 18000 btu, 1.5 ton, 2.25 hp, 8.1 a, inverter, r410, 1600 g

Mbsm.pro, air conditioner, Kf-50gw, 18000 btu, 1.5 ton, 2.25 hp, 8.1 a, inverter, r410, 1600 g




Mbsm.pro, 3HP, Panasonic, Compressor, Air Conditioner, 2js438d3fe02, j43ex, 18000BTU, 2 ton, 3hp, r22, Malaysia Panasonic

Product Description

Pananasonic/Matsushita compressor,Panasonic air conditioner parts,Panasonic rotary compressor  2JS438D3FE02

Product details

MODEL

PERFORMANCE

CAPACITY

TESTING

NOMINAL

TNPUT

CURRENT

COP

cm3/r

POWER

CAPACITY

KW

A

W/W

 

SOURCE

KW

BTU/H

 

 

 

 

JT170GA-Y1

380V/50Hz

15.6

53200

4.59

8.1

3.4

84

JT125GABTAL

220V/60Hz

13.9

47400

4.09

12

3.4

63.2

JT160GABTAL

220V/60Hz

17.4

59400

5.12

15.2

3.4

79.2

JT170GABTAL

220V/60Hz

18.6

63500

5.47

16.1

3.4

84

JT90GABY1L

380V/50Hz

8.41

28700

2.47

4.36

3.4

45.8

JT95GABY1L

380V/50Hz

9.07

30900

2.67

4.62

3.4

49.4

JT125GABY1L

380V/50Hz

11.7

39900

3.44

6

3.4

63.2

Moel Capacity Input power COP Power source Capacitance Refregerant     Dia(C) Angle
  W BTU/H W         mm(A) height mm(A) mm 0
Domestic/Europe 2V32S225AUA 5380 18630 1700 3.165 220V/50HZ 60/UF/370V R22 249 327 φ75 V/70°
  2V34S225AUA 5820 19860 1880 3.096 220V/240V/50HZ 50UF/370V R22 249 327 φ75 V/70°
  2V36S225AUA 6100 20815 1970 3.096 220V/50HZ 50UF/370V R22 249 297 φ75 V/70°
  2V36S225BUA 6140 20950 1980 3.101 220V/240V/50HZ 50UF/400V R22 249 327 φ75 V/70°
  2V38S225AUA 6615 22530 2070 3.196 220V/50HZ 60UF/370V R22 274 355 φ90 V/70°
  2V40S225AUA 6940 23200 2160 3.213 220V/50HZ 60UF/370V R22 274 355 φ90 V/70°
  2V42S225AUA 7200 24565 2340 3.077 220V/50HZ 50UF/370V R22 274 355 φ90 V/70°
  2VS356WW2AA04 7280 24840 2435 2.99 3PH/380V/50HZ _ R22 277 379 L TUBE V/90°
Tropical(T3) 2V36S225CUA 6375 21750 2020 3.156 200V/240V/50HZ 50UF/370V R22 254 350 φ90 V/70°
  2V34*** 7100 24225   200V/60HZ 50UF/370V R22  
  2V36*** 6100 20815   220V/240V/50HZ 50UF/370V R22  
    7500 25590   220V/60HZ 50UF/370V R22  
  2V42*** 7200 24565   220V/240V/50HZ 50UF/370V R22  

1) R22,  220V-240V / 380V ~ 50HZ   

Model Capacity Capacitor Voltage gas pallet
W BTU/H
2R11B225ASE 1745 5954 12.5UF/460v 220V-240V 50HZ R22 64
2P14S225ANE 2220 7575 30uf/370v 220V-240V 50HZ R22 60
2P17S225ANQ 2770 9451 30uf/370v 220V-240V 50HZ R22 60
2P20C225BNG 3245 11072 30uf/400v 220V-240V 50HZ R22 50
2K22S225BUA 3835 13085 35uf/370v 220V-240V 50HZ R22 50
2K25S225BUA 4245 14475 40uf/370v 220V-240V 50HZ R22 50
2K28C225DUA 4665 15900 45uf/370v 220V-240V 50HZ R22 40
2V32S225AUA 5410 18459 60uf/370v 220V-240V 50HZ R22 40
2V34S225AUA 5810 19824 60uf/400v 220V-240V 50HZ R22 40
2V36S225BUA 6140 20950 50uf/400v 220V-240V 50HZ R22 40
2V42S225AUA 7200 24566 50uf/370v 220V-240V 50HZ R22 40
2V44W385AUA 7670 26154 60uf/370v 380V 50HZ R22 40
2V47W385AUA 8235 28098 60uf/400v 380V 50HZ R22 40

2) R22,  220V / 115V~ 60HZ  

Model HP Capacity(btu) Voltage/Refrigerant pallet
2R11S3R236A6A 0.75HP 7200 R22 220V~60HZ 60
2P14S3R236A1A 1HP 9200 R22 220V~60HZ 50
2P19S3R236A1A 1.5HP 12700 R22 220V~60HZ 50
2P20S236A1G 1.5HP 13400 R22 220V~60HZ 50
2K25S236AHA 2HP 17900 R22 220V~60HZ 50
2K28C226AUC(T3) Big 2HP 20700 R22 220V~60HZ 40
2V34S236AUA 2.5HP 24900 R22 220V~60HZ 40
2P14S126B1L 1HP 9200 R22 115V~60HZ 60
2P19S126B1F 1.5HP 12700 R22 115V~60HZ 50



Mbsm.pro, Fufw12caw-ag, air conditioner, Fresh, turbo, Cooling, heating, 12000 Btu, 1.5 hp, 1 ton, r410a, 850 grams, 8 Bar, 115 psi

Mbsm.pro, Fufw12caw-ag, air conditioner, Fresh, turbo, Cooling, heating, 12000 Btu, 1 ton, r410a, 850 grams

850 grams. The device is 12000, which means one ton of gas is 410. You have to make a vacuum before shipping, and the bottle must be inverted. Charge it according to the weight and the amp

  • BRAND Fresh
  • CAPACITY 1.5 HP
  • COOLING TYPE cold and hot
  • wall INSTALLATION
  • MODEL FUFW12H