mbsm.pro , CUBIGEL Compressor GX21TB, 220-240 VOLTS, 5/8 HP , R134a
mbsm.pro , CUBIGEL Compressor GX21TB, 220-240 VOLTS, 5/8 HP , R134a
CUBIGEL Compressor GX21TB
TECHNICAL DETAILS
- GX21TB
- 220-240/1/50 VOLTS
- 5/8 HP
- R134a
mbsm.pro , CUBIGEL Compressor GX21TB, 220-240 VOLTS, 5/8 HP , R134a
TECHNICAL DETAILS
The error E6 comes from the engine, it is the electronic engine card if it is an inverter range.
Communication error E6 Between Outside and inside
* Test cable connection
* Test Inside Unit First without cable
* Test Outside unit without cable
* Check Fluid Pressure
* Test Fan Rotation
* Test Condensateur fonction