PDF , HVAC et Refrigeration Parts, Copper, Chemicals, Compressors, Controls, Coils, Fans & Motors, Electronics, Service Tools, Supplies

PDF , HVAC et Refrigeration Parts, Copper, Chemicals, Compressors, Controls, Coils, Fans & Motors, Electronics, Service Tools, Supplies




Tableau de conversion d’unités

  1.  
  2. Tableau de conversion d’unités
    Acceleration
    foot/second2, meter/second2, gal, galileo, inch/second2
    1 m/s2 = 3.28084 ft/s2 = 100 cm/s2 = 39.37 inch per second squared (inch/s2)
    1 ft/s2 = 0.3048 m/s2 = 30.48 cm/s2
    1 g = 9.80665 m/s2 = 32.17405 ft/s2
    Angle
    1 circle = 360 degrees = 400 grades = 21600 minutes = 6.28318 radians = 12 signs
    1 circumference = 360 degrees = 6.28318 radians
    1 radian = 0.15915 circumference = 57.29578 degree = 3437.747 minute = 0.63662 quadrant = 0.15915 revolution = 206265 second
    Area
    acre, are, barn, sq.ft., sq.in., foot2, hectare, inch2, mile2, section, meter2, township, yard2, hectares
    1 m2 = 1550 in2 = 10.764 ft2 = 1.1968 yd2 = 3.861×10-7 mile2
    1 ft2 = 0.0929 m2 = 144 in2 = 0,1111 yd2 = 3.587×10-8 mile2
    1 in2 = 6.452 cm2 = 6.452×10-4 m2 = 6.944×10-3 ft2 = 7.716×10-4 yd2 = 2.491×10-10mile2
    1 yd2 = 0.8361 m2 = 1,296 in2 = 9 ft2 = 0.3228×10-6 mile2
    1 mile2 = 2.590×106 m2 = 0.4015×1010 in2 = 2.788×107 ft2 = 3.098×106 yd2=640 Acres
    1 acre = 1/640 square mile = 0.404686 ha (Hectares) = 4,046.86 m2 = 43,560.174 Sq.Ft. (Int) = 43,560 Sq.Ft. (US Survey) = 4840 Sq.Yds. = 40.46873 are
    1 km2 = 102 ha2 = 106 m2 = 1010 cm2 = 1012 mm2
    1 ha (Hectare) = 104 m2 = 108 cm2 = 1010 mm2 = 2.471 Acres
    1 cm2 = 10-4 m2 = 0.155 in2
    1 mm2 = 1.55×10-3in2
    1 township = 36 square mile = 23040 acre = 36 section = 9.323957 107 m2 = 9324 hectare = 93.24 square kilometer
    1 section = 1 square mile = 2.59 106 m2 = 2.59 square kilometer = 259 hectare = 3.0976 106 square yards = 640 acre =
    1 are = 0.024711 acre (Int) = 1 sq dekameter = 1076.39 sq foot = 100 sq meter = 3.86102×10-5 sq mile = 119.599 sq yard
    1 barn = 1×10-24 sq cm
    1 centiare = 0.01 are = 10.764 sq foot = 1550 sq inch = 1 sq meter = 1.19599 sq yard
    1 circular mil = 1×10-6 circular inch = 5.06707×10-6 sq cm = 7.85398×10-7 sq inch = 0.000507 sq mm = 0.7854 sq mill
    1 hectare = 2.471 acre 0 100 are = 1×108 sq cm = 107639.1 sq foot = 10000 sq meter = 0.00386 sq mile = 395.367 sq rod
    Capacitance
    1 abfarad = 1×109 farad = 1×1015 microfarad = 8.98755×1020 statfarad
    1 farad = 1×10-9 abfarad = 1.00049 farads (Ínt) = 1×106 microfarad = 8.98755×1011statfarad
    Conductance
    1 abmho = 1000 megamho = 1×109 mho = 8.98755×1020 statmho
    Current
    1 abampere = 10 ampere = 1.03638×10-4 faraday/sec(chem) = 2.99792×1010statampere = 1 biot
    1 ampere = 0.1 abampere = 1.00015 ampere (Int) = 1 coulomb/sec = 1.03638×10-5faraday/sec (chem) 1×106 microampere = 1000 milliampere = 2.99792×109statampere
    1 ampere (Int) = 0.99985 ampere
    1 biot = 10 ampere
    Density
    kg/cubic meter, gram/centimeter3, lmb/cubic inch, lbm/cubic foot, slug/cubic foot, kilogram/cubic meter, lbm/gallon (US liq)
    Density Water 1,000 kg/m3 = 62.43 Lbs./Cu.Ft = 8.33 Lbs./Gal. = 0.1337 Cu.Ft./Gal.
    1 lb/ft3 = 16.018 kg/m3 = 0.016 g/cm3 = 0.00926 oz/in3 = 2.57 oz/gal (Imperial) = 2.139 oz/gal (U.S.) = 0.0005787 lb/in3 = 27 lb/yd3 = 0.161 lb/gal (Imperial) = 0.134 lb/gal (U.S) = 0.0121 ton/yd3
    1 slug/ft3 = 515.379 kg/m3
    1 kg/l = 62.43 lb/ft3
    1 kg/m3 = 0.001 g/cm3 = 0.0005780 oz/in3 = 0.16036 oz/gal (Imperial) = 0.1335 oz/gal (U.S.) = 0.0624 lb/ft3 = 0.000036127 lb/in3 = 1.6856 lb/yd3 = 0.010022 lb/gal (Imperial) = 0.008345 lb/gal (U.S) = 0.0007525 ton/yd3
    Electric Charge
    1 abcoulomb = 0.00278 ampere-hour = 10 coulomb = 6.24151×1019 electronic charge = 1.03632×10-4 faraday (chem) = 2.99792×1010 statcoulomb
    1 ampere hour = 360 abcoulomb = 3600 coulomb = 0.03731 faraday (chem)
    1 coulomb = 0.1 abcoulomb = 0.000278 ampere hour = 1 ampere second = 1.00015002 coulomb (Int) = 1.0363×10-5 faraday (chem) = 1.0360×10-5 faraday (phys) = 2.9979×109 statcoulomb
    Electromotive Force, Voltage Difference
    abvolt = 0.01 microvolt = 1×10-5 millivolt = 1×10-8 volt
    Energy
    British Thermal Unit (Btu), calorie, joule, kilojoule, electron volt, erg, foot lbf, foot poundal, kilocalorie, kilowatt hour, watt hour,
    1 J (Joule) = 0,1020 kpm = 2.778×10-7 kWh = 2.389×10-4 kcal = 0.7376 ft lbf = 1 (kg m2)/s2 = 1 watt second = 1 Nm = 1 ft lb = 9.478×10-4 Btu
    1 kpm = 9.80665 J = 2.724×10-6 kWh = 2.342×10-3 kcal = 7.233 ft lbf = 9.295×10-3 Btu
    1 kWh = 3.6×106 J = 3.671×105 kpm = 859.9 kcal = 2.656×106 ft lbf = 3.412×103 Btu
    1 kJ = 1 kNm = 1kWs = 103 J = 0.947813 Btu = 737.6 ft lbf = 0.23884 kcal
    1 Btu (British thermal unit) = 1,055.06 J = 107.6 kpm = 2.92875×10-4 kWh = 251.996 calorie = 0.252 kcal = 777.649 ft lbf = 1.0544×1010 erg = 0.293 watt hour = 0.999331 Btu (Int Steam Tab) = 0.998560 Btu (mean) = 25020.1 foot-poundal = 107.514 kg force meter = 1.0751×107 gram-force cm = 0.000393 hp-hour = 10.456 liter atm = 1054.35 wattsecond
    1 cal = 4.186 J
    1 kcal = 4186,8 J = 426,9 kp m = 1.163×10-3 kWh = 3.088 ft lbf = 3.9683 Btu = 1,000 cal
    1 ft lbf (foot pound force) = 1.3558 J = 0.1383 kp m = 3.766×10-7 kWh = 3.238×10-4kcal = 1.285×10-3 Btu
    1 hp h (horse power hour) = 2.6846×106 J = 0.7457 kWh
    1 erg = 1 (g cm2)/s2 = 10-7 J
    1 eV = 1.602×10-19 J
    1 Q = 1018 Btu = 1.055×1021 J
    1 Quad = 1015 Btu
    1 Therm = 100,000 Btu
    1 kg m = 7.233 ft lb = 0.00929 Btu = 9.806 Joule
    Energy per unit mass
    1 kJ/kg = 1 J/g = 0.4299 Btu/ lbm = 0.23884 kcal/kg
    Flow – see Volume flow
    Force
    dyne, kilogram force (kgf), kilopound force, kip, lbf (pound force), ounce force (avoirdupois), poundal, newton
    1 N (Newton) = 0.1020 kp = 7.233 pdl = 7.233/32.174 lbf = 0.2248 lbf = 1 (kg m)/s2 = 105 dyne = 1/9.80665 kgf
    1 lbf (Pound force) = 4.44822 N = 0.4536 kp = 32.17 pdl = 4.448×105 dyn
    1 dyn = 1 (g cm)/s2
    1 kg has a weight of 1 kp
    1 kp (Kilopond) = 9.80665 N = 2.205 lbf = 70.93 pdl
    1 pdl (Poundal) = 0.13826 N = 0.01409 kp = 0.03108 lbf
    Frequency
    1 hertz = 1 cycle/sec
    Heat flow rate
    1 Btu/sec = 1,055.1 W
    1 kW (kJ/s) = 102.0 kpm/s = 859.9 kcal/h = 3,413 Btu/h = 1.360 hk = 1.341 hp = 738 ft lb/s = 1,000 J/s = 3.6×106 J/h
    1 kpm/s = 9.8067×10-3 kW = 8.432 kcal/h = 32.47 Btu/h = 0.01333 hk = 0.01316 hp = 7.237 ft lb/s
    1 kcal/h = 1.163×10-3 kW = 0.1186 kpm/s = 3.969 Btu/h = 1.582×10-3 hk = 1.560×10-3hp = 0.8583 ft lb/s
    1 Btu/h = 2.931×10-4 kW = 0.0299 kpm/s = 0.252 kcal/h = 3.986×10-4 hk = 3.939×10-4 hp = 0.2163 ft lb/s
    1 kcal/h = 1.16×10-3 kW
    1 hk (metric horse power) = 0.735499 kW = 75.00 kpm/s = 632.5 kcal/h = 2,510 Btu/h = 0.9863 hp = 542.8 ft lb/s
    1 hp = 0.74570 kW = 76.04 kpm/s = 641.2 kcal/h = 2,545 Btu/h = 1.014 hk = 550.3 ft lb/s
    1 ft lb/s = 1.35501 kW = 0.1382 kpm/s = 1.165 kcal/h = 4.625 Btu/h = 1.843×10-3 hk = 1.817×10-3 hp
    Heat flux
    1 Btu/ft2 = 2.713 kcal/m2 = 2.043×104 J/m2K
    1 Btu/ ft2 h = 3.1525 W/m2
    1 Btu/ft2 oF = 4.88 kcal/m2K = 2.043×104 J/m2K
    1 kcal/m2 = 0.369 Btu/ft2
    1 kcal/m2K = 0.205 Btu/ft2oF
    Heat generation per unit volume
    1 Btu/ft3 = 8.9 kcal/m3 = 3.73×104 J/m3
    1 Btu/ft3 h = 10.343 W/m3
    1 kcal/m3 = 0.112 Btu/ft3
    Heat generation per unit mass
    1 Btu/lb = 0.556 kcal/kg = 2,326 J/kg
    1 kcal/kg = 1.800 Btu/lb
    Heat transfer coefficient
    1 Btu/ft2 h oF = 5.678 W/m2 K = 4.882 kcal/h m2 oC
    1 W/m2K = 0.85984 kcal/h m2 oC = 0.1761 Btu/ ft2 h oF
    1 kcal/h m2 oC = 1.163 W/m2K = 0.205 Btu/ ft2 h oF
    Hydraulic Gradients
    1 ftH2O/100 ft = 0.44 psi/100 ft = 9.8 kPa/100 m = 1000 mmH2O/100 m
    1 psi/100 ft = 2.3 ftH2O/100 ft = 2288 mmH2O/100 ft = 22.46 kPa/100 m
    Inductance
    abhenry = 1×10-9 henry
    nery = 1×109 abhenry = 0.9995 henry (Int) = 1000 millihenry = 1.113×10-12 stathenry
    Information Storage
    1 bit = 0.125 byte (computers)
    1 byte = 8 bit
    Length
    feet, meters, centimeters, kilometers, miles, furlongs, yards, micrometers, inches,angstrom, cubit, fathom, foot, hand, league, light year, micron, mil, nautical mile, rod,
    1 m (meter) = 3.2808 ft = 39.37 in = 1.0936 yd = 6.214×10-4 mile
    1 km = 0.6214 mile = 3281 ft = 1094 yds
    1 in (inch) = 25.4 mm = 2.54 cm = 0.0254 m = 0.08333 ft = 0.02778 yd = 1.578×10-5mile
    1 ft (foot) = 0.3048 m = 12 in = 0.3333 yd = 1.894×10-4 mile = 30.48 cm = 304.8 mm
    1 mm = 10-3 m
    1 cm = 10-2 m = 0.3937 in = 0.0328 ft = 1×108 Aangstrom = 0.03281 foot = 0.0984 hand (horses) = 0.3937 inch = 1×10-5 kilometer = 0.0497 link (Gunter) = 0.0328 (Ramden)  = 1000 micrometer = 1000 micron = 5.3996×10-6 mile (naut) = 6.2137×10-6 mile (US statute) = 10 millimeter = 1×107 millimicron = 393.7 mil = 2.371 picas (printers) 28.4528 point (printers) = 0.00199 rod (US Survey) = 0.01094 yard
    1 mm = 0.03937 in
    1 Aangstrom = 10-10 m = 1×10-8 cm = 3.937×10-9 inch = 1×10-4 micrometer = 0.0001 micron = 0.1 millimicron
    1 mile = 1.6093 km = 1,609.3 m = 63,346 in = 5,280 ft = 1,760 yd
    1 mil (Norway and Sweden) = 10 kilometres
    1 nm (nautical mile, sea mile) = 1,852 metres = 1.151 mile = 6076.1 feet = 0.016667 degree of latitude
    1 yd (yard) = 0.9144 m = 36 in = 3 ft = 5.682×10-4 mile
    1 Furlong = 660 feet = 40 rods = 1/8 mile
    1 rod = 5.5 yards
    1 land league = 3 miles
    1 Fathom = 6 feet = 1.828804 meters
    1 astronomical unit = 1.496×108 kilometer
    1 cable (UK) = 0.00167 degree latitude = 185.37 meter
    1 cable length (US Survey) = 120 fathom (US Survey) = 720 foot (US Survey) = 219.456 meter
    1 caliber = 0.01 inch = 0.254 mm
    1 chain (Gunter or US Survey) = 2011.7 centimeter = 66.00013 foot = 66 foot (US Survey) = 0.1 Furlong (US Survey) = 792 inch (US Survey) = 100 link (Gunter) = 66.00013 link (Ramden) = 20.117 meter = 0.0125 mile (US statute) = 4 rod (US Survey) = 22 yard (US Survey)
    1 light year = 63241.08 astronomical unit = 9.46073×1012 kilometer = 5.8786×1012 mile (US statute) = 0.306601 parsec
    Luminous Emittance (Illuminance)
    1 lumen/sq ft = 1 foot candle = 1×104 lux = 1 phot
    1 lux = 0.0929 foot candle = 1 lumen /sq meter = 0.0001 phot
    Luminous Flux
    1 candle power = 12.566 lumen
    1 lumen = 1 candela steradian = 0.07958 candle power (spherical) = 0.0015 watt
    Luminous Intensity
    1 candela = 1.091 hefner candle (Germ) = 1 lumen/steradian
    Magnetic Flux Density
    1 gamma flux = 1×10-5 gauss =  1 x10-6 gram = 1 microgram = 1×10-9 tesla
    1 gauss = 0.9997 gauss (Int) = 1×105 gamma = 1 gilbert/cm = 1 maxwell/sq cm = 1 line/sq cm = 6.4516 line/sq inch = 1×10-4 tesla  = 1×10-8 weber/sq cm = 6.452×10-8weber/sq inch = 1×10-4 weber/sq meter
    Magnitude of a Physical Quantity (Power or intensity relative to a specified or implied reference level)
    1 bel = 10 decibel
    1 decibel = 0.1 bel
    Mass, Weight
    pounds, kilograms, grams, ounces, grains, tons (long), tons (short), tons (metric), carat, grain, ounce mass, pound mass (lbm), slug, tonne
    1 kg = 1,000 gram = 2.2046 lb = 6.8521×10-2 slug
    1 lb = 16 oz = 0.4536 kg = 453.6 g = 7000 grains = 0.03108 slug
    1 slug = 14.594 kg = 32.174 lbm
    1 grain = 0.000143 lb = 0.0648 g
    1 g = 15.43 grains = 0.0353 oz = 0.002205 lb
    1 qt = 0.9464 liters
    1 metric ton (or tonne) = 1 tonne métrique = 1000 kg = 106 g = 109 mg = 0.907 short tons
    1 short ton = 2000 lbs = 907.18474  kg
    1 long ton = 2240 pounds = 1,016.0469088 kg
    1 oz (ounce) = 28.35 g = 437.5 grains = 0.0625 lb = 0.0000279 long ton (UK) = 0.00003125 long ton (US) = 0.000558 long hundredweight (UK) = 0.000625 long hundredweight (US) = 0.004464 stone = 16 dram
    1 troy pound = 12 troy ounces
    1 scruple = 20 grains
    1 dram = 3 scruples
    1 apothecary ounce = 8 drams
    1 apothecary pound = 12 apothecary ounces
    1 pennyweight = 24 grains
    1 Gal. H2O = 8.33 Lbs. H2O
    1 cental (US) = 45.359 kilogram = 100 pound
    1 carat (metric) = 3.0865 grain = 0.2 gram = 200 milligram
    1 hectogram = 100 gram = 0.26769 pound (apoth or troy) = 0.2205 pound (avdp)
    Density, Specific Weight and Specific Gravity – An introduction and definition of density, specific weight and specific gravity. Formulas with examples.
    Mass flow rate
    1 lb/h = 1.26×10-4 kg/s
    1 lb/s = 0.4536 kg/s
    1 lb/min = 7.56×10-3 kg/s = 27.216 kg/s
    1 kg/s = 3,600 kg/h = 132.28 lb/min
    1 kg/h = 2.778×10-4 kg/s = 3.67×10-2 lb/min
    Moment of Inertia
    1 kg m2 = 10000 kg cm2 = 54675 ounce in2 = 3417.2 lb in2 = 23.73 lb ft2
    Power
    horsepower, kilowatt, watt,btu/second, calorie/second, foot lbf/second, kilocalorie/second
    1 W = 1 kg m2/s3 = 1 Nm/s = 1 J/s
    1 kW = 1,000 Watts = 3,412 Btu/h = 737.6/550 British hp = 1.341 British hp = 103/9.80665 kgf m/s = 737.6 ft lbf/s = 103/(9.80665 75) metric hp
    1 hp (English horse power) = 745.7 W = 0.746 kW = 550 ft lb/s = 2,545 Btu/h = 33.000 ft lb/m = 1.0139 metric horse power ~= 1.0 KVA
    1 horsepower (mech) = 2542.47 Btu (mean)/hr = 42.375 Btu (mean)/min = 0.7062 Btu (mean)/sec = 6.416×105 calorie/hr (termo) = 6.412×105 calorie (IST)/hr = 6.4069×105calorie(mean)/hr = 10694 calorie/min (thermo) = 10686 calorie (IST)/min = 10678 calorie (mean)/min = 10.686 calorie, kg/min (IST) = 7.457×109 erg/sec = 1980000 foot pound-force/hr = 33000 foot pound-force/min = 550 foot pound-force/sec = 0.076 horsepower (boiler) = 0.9996 horsepower (electric) = 1.0139 horsepower (metric) = 745.7 joule/sec = 0.7457 kilowatt = 0.7456 kilowatt (Int) = 0.212 ton of refrigeration = 745.7 watt
    1 horsepower (boiler) = 33445.6 Btu (mean)/hr = 140671.6 calorie/min (thermo) = 140469.4 calorie (mean)/min = 140742.3 calorie (20oC)/min 9.8095×1010 erg/sec = 434107 foot-pound-force/min = 13.1548 horsepower (mech) = 13.1495 horsepower (electric) = 13.3372 horsepower (metric) = 13.1487 horsepower (water) = 9809.5 joule/sec = 9.8095 kilowatt
    1 horsepower (electric) =  2547.16 Btu/hr (thermo) = 2545.46  Btu (IST)/hr = 2543.49 Btu (mean)/hr = 178.298 calorie/sec (thermo) = 641.87 calorie, kg/hr (thermo) = 7.46×109 erg/sec = 33013 foot pound-force/min = 550.2 foot pound-force/sec = 1.0004 horsepower (mech) = 0.07605 horsepower (boiler) = 1.01428 horsepower (metric) = 0.99994 horsepower (water) = 746 joule/sec = 0.746 kilowatt = 746 watt
    1 horsepower (metric) = 2511.3 Btu/hr (thermo) = 2509.6 Btu (IST)/hr = 2507.7 Btu (mean)/hr = 6.328×105 calorie/hr (thermo) = 6.324×105 calorie (IST)/hr = 6.319×105calorie (mean)/hr = 7.35×109 ergs/sec = 32548.6 foot pound-force/min = 542.476 foot pound-force/sec = 0.9863 horsepower (mech) = 0.07498 horsepower (boiler) = 0.9859 horsepower (electric) = 0.98587 horsepower (water) = 75 kg-force meter/sec (kg m/s) = 0.7355 kilowatt =   735.499 W = 75 kg m/s
    1 horsepower (water) = 33015 foot pound-force/min = 1.00046 horsepower (mech) = 0.07605 horsepower (boiler) = 1.00006 horsepower (electric) = 1.01434 horsepower (metric) = 0.746043 kilowatt
    1 refrigeration Ton = 12,000 Btu/h cooling = 3.516 kW = 3,025.9 k Calories/h
    1 cooling tower Ton = 15,000 Btu/h = 3,782 k Calories/h
    1 ft lb/s = 1.3558 W
    1 Btu/s = 1055.1 W
    1 Btu/h = 1 Btuh = 0.293 W = 0.001 MBH
    1 cheval vapeur (French) = 0.98632 horsepower
    Power per unit area
    1 W/m2 = 0.3170 Btu/(h ft2) = 0.85984 kcal/(h m2)
    Pressure
    atmosphere, centimeters of mercury, foot of water, bar, barye, centimeter of water, dyne/centimeter2, inch of mercury, inch of water, kgf/centimeter2, kgf/meter2, lbf/foot2, lbf/inch2 (psi), millibar, millimeter of mercury, pascal, torr, newton/meter2
    Standard Atmospheric Pressure 1 atm = 101.325 kN/m2 = 1.01325 bar = 101.325 kPa = 14.7 psia = 0 psig = 29.92 in Hg = 760 torr = 33.95 Ft.H2O = 407.2 In.W.G (Water Gauge) = 2116.8 Lbs./Sq.Ft.
    1 N/m2 = 1 Pa = 1.4504×10-4 lb/in2 = 1×10-5 bar = 4.03×10-3 in water = 0.336×10-3 ft water = 0.1024 mm water = 0.295×10-3 in mercury = 7.55×10-3 mm mercury = 0.1024 kg/m2 = 0.993×10-5 atm
    1 Pa = 10-6 N/mm2 = 10-5 bar = 0.1020 kp/m2 = 1.02×10-4 m H2O = 9.869×10-6 atm = 1.45×10-4 psi (lbf/in2)
    1 N/mm2 = 106 Pa = 10 bar = 1.020×105 kp/m2 = 102.0 m H2O = 9.869 atm = 145.0 psi (lbf/in2)
    1 mmHg = 1 torr = 0.01934 lb/in2
    1 atm = 101,325 Pa (N/m2) = 1.013×102 kN/m2 = 1.033×104 kp/m2 = 1.033 kp/cm2 = 1.013 bar = 14.696 psi (lb/in2) = 407.1 in H2O at 62 0F (16.7 oC) = 33.9 ft H2O at 62 0F (16.7 oC) = 10.33 m H2O at 62 0F (16.7 oC) = 29.92 in mercury at 62 0F (16.7 oC) = 760 mm mercury at 62 0F (16.7 oC) = 760 torr
    1 bar = 1×105 Pa (N/m2) = 0.1 N/mm2 = 10,197 kp/m2 = 10.20 m H2O = 0.98692 atm = 14.5038 psi (lbf/in2) = 1×106 dyne/sq cm = 750 mmHg = 1×106 barye (French) = 75.0062 cm Hg (0oC) = 33.4883 ft H2O (60oF) = 1019.72 gram-force/sq cm = 29.530 in Hg (32oF) = 1.01972 kg-force/sq cm = 1000 millibar = 2088.54 pound-force/sq foot
    1 kp/m2 = 9.81 Pa (N/m2) = 9.807×10-6 N/mm2 = 10-3 m H2O = 1 mm H2O = 0.9681×10-4 atm = 1.422×10-3 psi (lb/in2) = 0.0394 in H2O = 0.0736 mm mercury
    1 psi (lb/in2) = 144 psf (lbf/ft2) = 6,894.8 Pa (N/m2) = 6.895×10-3 N/mm2 = 6.895×10-2bar = 27.71 in H2O at 62oF (16.7oC) = 703.1 mm H2O at 62oF (16.7oC) = 2.0416 in mercury at 62oF (16.7oC) = 51.8 mm mercury at 62oF (16.7oC) = 703.6 kg/m2 = 0.06895 atm = 2.307 Ft. H2O = 16 ounces
    1 psf (lbf/ft2) = 47.88 N/m2 (Pa) = 0.006944 lbf/in2 (psi)
    1 dyn/cm2 = 145.04×10-7 lbf/in2
    1 in mercury (Hg) = 3,376.8 N/m2= 0.49 lb/in2 = 12.8 in water
    1 Ounce = 1.73 In.W.C.
    1 Ft.H2O = 0.4335 psi = 62.43 Lbs./Sq.Ft.
    1 in water = 248.8 N/m2= 0.0361 lb/in2 = 25.4 kg/m2 = 0.0739 in mercury
    1 m H2O = 9806.7 Pa = 9.807×10-3 N/mm2 = 0.0987 bar = 1,000 kp/m2 = 0.09678 atm = 1.422 psi (lbf/in2)
    1 mm water = 9.81 Pa (N/m2) = 1 kg/m2 = 0.0736 mm mercury = 0.9677×10-4 atm
    1 mm mercury = 0.0193 lb/in2 = 133 N/m2 = 12.8 mm water
    1 barye (French) = 1.0 dyne/sq cm = 0.10 newton/sq meter = 0.10 Pascal
    Note! When using pressure units based on liquid columns (like mm Water, in Water, mm Hg …) – be aware that densities of liquids varies with temperature. For more exact conversions consult temperature density sources for the actual liquids.
    Radioactivity
    1 becquerel = 2.7027×10-11 curie = 1 disintegration/sec
    Resistance, Electrical
    1 abohm = 1×10-15 megohm = 0.001 microohm = 1×10-9 ohm
    Rotation
    revolutions,
    1 r/min (rpm) = 0.01667 r/s = 0.105 rad/s
    1 r/s = 60 r/min = 6.28 rad/s
    1 rad/s = 9.55 r/min (rpm) = 0.159 r/s (rps)
    Specific energy, enthalpy, entropy
    1 Btu/lbm = 2,326.1 J/kg = 0.55556 kcal/kg = 778.2 ft lbf / lbm = 3.9 10-4 hp hr / lbm = 5.4 lbf/in2 / lbm/ft3 = 0.237 kp m / g = 5.56 10-4 kcal/g = 2.326 kJ/kg
    1 J/kg = 4.299×10-4 Btu/lbm = 2.388×10-4 kcal/kg
    1 kcal/kg = 1.80 Btu/lbm = 4,187 J/kg
    Specific heat capacity
    1 J/(kg K) = 2.389×10-4 kcal/(kg oC) = 2.389×10-4 Btu/(lbm oF)
    1 kJ/(kg K) = 0.2389 kcal/(kg oC) = 0.2389 Btu/(lbm oF)
    1 Btu/(lbm oF) = 4,186.8 J/ (kg K) = 1 kcal/(kg oC)
    1 kcal/(kg oC) = 4,186.8 J/ (kg K) = 1 Btu/(lbm oF)
    Specific Volume
    1 m3/kg = 16.02 ft3/lbm = 27680 in3/lbm = 119.8 US gal/lbm = 1000 liter/kg
    1 liter/kg = 0.016 ft3/lbm = 27.7 in3/lbm = 0.12 US gal/lbm = 0.001 m3/kg
    1 ft3/lbm = 1728 in3/lbm = 7.48 US gal/lbm = 62.43 liter/kg = 0.062 m3/kg
    1 in3/lbm = 0.00058 ft3/lbm = 0.0043 US gal/lbm = 0.036 liter/kg = 0.000036 m3/kg
    1 US gal/lbm = 0.134 ft3/lbm = 231 in3/lbm = 8.35 liter/kg = 0.0083 m3/kg
    Temperature
    celsius, rankine, kelvin, centigrade, fahrenheit,
    1 oC = 1.8 oF
    1 oF = 0.555 oC
    0 oC corresponds to 32 oF, 273.16 K and 491.69 R
    1 oR = 5/9 K
    T(oF) = [T(oC)](9/5) + 32
    T(oF) = [T(K) – 273.15](9/5) + 32
    T(oC) = 5/9[T(oF) – 32]
    Thermal Conductivity
    1 W/(m K) = 0.85984 kcal/(h m oC) = 0.5779 Btu/(ft h oF)
    1 Btu/(ft h oF) = 1.731 W/(m K) = 1.488 kcal/(h m oC)
    1 kcal/(h m oC) = 1.163 W/(m K) = 0.6720 Btu/(ft h oF)
    Thermal Diffusivity
    1 ft2 /s = 0.0929 m2/s
    1 ft2 /h = 2.581×10-5 m2/s
    Thermal resistance
    1 (h oF)/Btu = 1.8958 K/W
    Time
    year, month, day, hour, minute, second, millisecond
    1 h = 3600 s = 60 min
    1 ms (millisecond) = 10-3 s
    1 μs (microsecond) = 10-6 s
    1 ns (nanosecond) = 10-9 s
    1 day (mean solar) = 1.0027379 day (sidereal) = 24 hour (mean solar) = 24.06571 hour (sidereal) = 0.0027397 year (calendar) = 0.002738 year (sidereal) = 0.002738 year (tropical)
    Torque, Moment
    foot-pound torque, newton-meter
    1 ft lb = 1.356 Nm
    Velocity, Speed
    foot/second, inch/second, meter/second, kilometer/hour, knot, mile/hour,nautical mile per hour
    1 ft/s = 0.3048 m/s
    1 ft/min = 5.08×10-3 m/s = 0.0183 km/h = 0.0114 mph
    1 mph = 0.44703 m/s = 1.609 km/h = 88 ft/min = 5280 ft/hr = 1.467 Ft./sec. = 0.8684 knots
    1 m/s = 3.6 km/h = 196.85 ft/min = 2.237 mph
    1 km/h = 0.2778 m/s = 54.68 ft/min = 0.6214 mph = 0.5396 knot
    1 knot (nautical mile per hour) = 0.514444444 m/s = 1.852 kilometers per hour = 1.1515 miles per hour= 1 nautical miles per hour
    1 League = 3.0 Miles
    1 cm/sec = 1.9685 foot/min = 0.0328 foot/sec = 0.036 km/hr = 0.0194 knots (Int) = 0.6 meter/min = 0.02237 mile/hr = 0.000373 mile/min
    Viscosity Dynamic
    1 lb/(ft s) = 1.4879 Pa s = 14.88 P = 1,488 cP = 0.1517 kp s/m2
    1 cP (Centipoise) = 10-3 Pa s = 0.01 Poise = 1.020×10-4 kp s/m2 = 6.721×10-4 lb/(ft s) = 0.00100 (N s)/m2 = 0.01 gram/(cm sec) = 2.4191 lb/(ft hr)
    1 kg/(m s ) = 1 (N s)/m2 = 0.6720 lbm/(ft s) = 10 Poise
    1 P (Poise) = 0.1 Pa s = 100 cP = 1.020×10-2 kp s/m2 = 6.721×10-2 lb/(ft s) = 0.1 kg/ms
    1 Pa s (N s/m2) = 10 P (Poise) = 103 cP = 0.1020 kp s/m2 = 0.6721 lb/(ft s)
    1 kp s/m2 = 9.80665 Pa s = 98.07 P = 9,807 cP = 6.591 lb/(ft s)
    1 reyns = 1 1bf s/in2 = 6894.76 Pa s
    Dynamic, Absolute and Kinematic Viscosity – An introduction to dynamic, absolute and kinematic viscosity and how to convert between CentiStokes (cSt), CentiPoises (cP), Saybolt Universal Seconds (SSU) and degree Engler.
    Viscosity Kinematic
    1 ft2/s = 0.0929 m2/s
    1 ft2/ h = 2.581×10-5m2/s
    1 St (Stokes) = 1×10-4 m2/s = 100 cSt = 1.076×10-3 ft2/s
    1 m2/s = 104 St = 106 cSt = 10.764 ft2/s= 38750 ft2/h
    1 cSt (Centistoke) = 10-6 m2/s = 0.01 Stokes = 1.076×10-5 ft2/s = 1 square mm/sec
    Volume
    barrel, gallon, cubic centimeter (cm3), cubic feet (foot3), cubic inch (inch3), cubic meter (meter3), cubic yard (yard3), quarts, liters, acre foot, board foot, bushel, cord, cup, dram, fluid ounce, peck, pint, quart, tablespoon, teaspoon,
    1 ft3 = 0.02832 m3= 28.32 dm3 = 0.03704 yd3 = 6.229 Imp. gal (UK) = 7.481 gal (US) = 1,728 cu inch = 2.296×10-5 acre foot = 12 board foot (timber) = 0.7786 bushel (UK) = 0.8036 bushel (US, dry) = 0.00781 cord (firewood) = 0.0625 cord foot (timber) = 28316.8 cu centimeter = 6.42851 gallon (US, dry) = 7.48052 gallon (US, liq) = 28.3168 liter = 996.614 ounce (UK, liq) = 957.506 ounce (US, liq) = 51.4281 pint (US, dry) = 59.84442 pint (US, liq) = 25.714 quart (US, dry) = 29.922 quart (US, liq)
    1 in3 = 1.6387×10-5 m3 = 1.639×10-2 dm3 (liter) = 16.39 cm3 = 16390 mm3 = 0.000579 ft3
    1 Gallon (U.S.) = 3.785×10-3 m3 = 3.785 dm3 (liter) = 231 in3 = 0.13368 ft3 = 4.951×10-3yd3 = 0.8327 Imp. gal (UK) = 4 Quarts = 8 Pints
    1 Imp. gallon (UK) = 4.546×10-3 m3 = 4.546 dm3 = 0.1605 ft3 = 5.946×10-3 yd3 = 1.201 gal (US)
    1 dm3 (Liter) = 10-3 m3 = 0.03532 ft3 = 1.308×10-3 yd3 = 0.220 Imp gal (UK) = 0.2642 Gallons (US) = 1.057 Quarts = 2.113 Pints
    1 yd3 = 0.7646 m3 = 764.6 dm3 = 27 ft3 = 168.2 Imp. gal (UK) = 202.0 gal (US) = 46,656 Cu.In. = 1616 Pints = 807.9 Quarts = 764.6 Liters
    1 pint (pt) = 0.568 dm3 (liter) = 16 fl. oz. (fluid ounce) = 28.88 in3
    1 km3 = 109 m3 = 1012 dm3 (liter) = 1015 cm3 = 1018 mm3
    1 cm3 = 0.061 in3 = 0.00042 board foot = 2.7496×10-5 bushel (UK) = 2.8378×10-5bushel (US, dry) = 3.5315×10-5 cu foot = 0.06102 cu inch = 1×10-6 cu meter = 1.308×10-6 cu yard = 0.28156 drachm (UK, liq) = 0.27051 dram (US, liq) = 0.000227 gallon (UK) = 0.00027 gallon (US, dry) = 0.000264 gallon (US, liq) = 0.0074 gill (UK) = 0.00845 gill (US) = 0.001 liter = 0.035195 ounce (UK, liq) = 0.033814 ounce (US, liq) = 0.00182 pint (US, dry) = 0.00211 pint (US, liq) = 0.00088 quart (UK) = 0.00091 quart (US, dry) = 0.00106 quart (US, liq)
    1 m3 = 103 dm3 (liter) = 35.31 ft3 = 1.3093 yd3 = 220.0 Imp. gal (UK) = 264.2 gal (US) = 61,023 Cu.In. = 35.31 Cu.Ft = 0.1 decistere
    1 Hogshead = 63 gallon = 8.42184 Cu.Ft
    1 barrel (UK) = 1.5 bag (UK) = 1.41541 barrel (US, dry) = 1.37251 barrel (US, liq) = 4.5 bushel (UK) = 4.64426 bushel (US, dry) = 5.77957 cu ft = 0.16366 cu meter =  36 gallon (UK) = 163.6592 liter
    1 barrel beer = 31.5 gallons beer
    1 barrel (US, oil) = 1.33 barrel (US, liq) = 5.61458 cu foot = 42 gallons (US, liq) = 158.9873 liter
    1 barrel (US, dry) = 0.969696 barrel (US, liq) = 3.28122 bushel (US, dry) = 4.0833 cu ft = 7056 cu inch = 0.11563 cu meter = 104.999 quart (US, dry)
    1 barrel (US, liq) = 1.03125 barrel (US, dry) = 0.75 barrel (US, oil) = 4.2109 cu foot = 7276.5 cu inch = 0.11924 cu meter = 26.22924 gallon (UK) = 31.5 gallon (US, liq) = 119.24 liter =
    1 bushel = 1.2445 Cu.Ft. = 32 Quarts (Dry) = 64 Pints (dry) = 4 Pecks
    1 bushel (UK) = 0.3333 bag (UK) = 1.03206 bushel (US) = 36368.7 cu cm = 1.28435 cu foot = 2219 cu inch = 8 gallon (UK) =  36.3687 liter
    1 bushel (US, dry) = 0.30476 barrel (US, dry) = 0.96894 bushel (UK) = 35239.07 cu cm = 1.24446 cu foot = 2150.42 cu inch = 0.03524 cu meter 0.04609 cu yard = 8 gallon (US, dry) = 9.30918 gallon (US, liq) = 35.23907 liter = 1191.57 ounce (US, liq) = 4 peck (US) = 64 pint (US, dry) = 32 quart (US, dry) = 37.23671 quart (US, liq)
    1 quart (qt) = 2 pints = 57.75 in3 = 1/8 dry quarts
    1 fluid ounce (fl. oz.) = 2 tablespoons = 1.805 in3 = 29.574 milliliters
    1 cord (firewood) = 128 cu foot = 8 cord foot (timber) = 3.6246 cu meter
    1 cord foot (timber) = 0.125 cord (firewood) = 16 cu foot
    1 peck = 8 dry quarts
    1 cup = 8 fl.oz. (fluid ounce)
    1 cup (metric) = 200 milliliter
    1 cup, tea = 0.25 pint = 142.06 milliliter
    1 board foot = piece of lumber 1 foot wide x 1 foot long x 1 inch thick = 2359.74 cu cm = 0.083333 cu foot = 144 cu inch
    1 acre foot = 43560 cu foot = 1233.482 cu meter = 1613.33 cu yard = 3.259×105 gallon (US liquid)
    1 acre inch = 3630 cu foot = 102.7901531 cu meter = 134.44 cu yard = 27154.286 gallon (US)
    1 bucket (UK) = 18184.35 cu cm = 4 gallon (UK)
    1 butt (UK. liq) = 16.2549 bushel (US) = 20.2285 cu foot = 0.57281 cu meter = 151.3197 gallon (US)
    1 chaldron (UK, liq) = 36 bushel (UK)
    1 dram (US, liq) = 3.6967 cu cm = 0.225586 cu inch = 1.04084 drachm (UK, liq) = 0.03125 gill (US) = 3.69669 millimeter = 60 minim (US) = 0.125 ounce (US, liq) = 0.0078125 pint (US, liq)
    1 fifth (US, liq) = 17.067 jigger (US, liq) = 0.75708 liter = 25.6 ounce (US, liq) = 1.6 pint (US, liq) = 25.6 pony (US, liq) = 0.8 quartt (US, liq) = 25.6 shot (US, liq)
    1 firkin (UK) = 1.125 bushel (UK) =  40914.8 cu cm = 1.44489 cu foot = 1.20095 firkin (US) = 9 gallon (UK) = 40.91481 liter = 72 pint (UK)
    1 hectoliter = 2.7496 bushel (UK) = 2.8378 bushel (US, dry) = 1×105 cu cm = 3.5315 cu foot = 26.417 gallon (US, liq) = 100 liter = 3381.4 ounce (US, liq) = 11.351 peck (US)
    Volume Flow
    1 dm3/s (kg/s water) = 13.20 Imp. gal (UK)/min
    1 m3/s = 3,600 m3/h = 1,000 dm3(liter)/s = 35.32 ft3/s = 2,118.9 ft3/min = 13,200 Imp.gal (UK)/min = 15,852 gal (US)/min
    1 m3/h = 2.7778×10-4 m3/s = 0.2778 dm3(litre)/s = 9.810×10-3 ft3/s = 0.5886 ft3/min (cfm) = 3.667 Imp.gal (UK)/min = 4.403 gal (US)/min
    1 m3/h = 103 dm3(litre)/h = 16.67 dm3(litre)/min = 0.27878 dm3(litre)/s
    1 ft3/min = 1.7 m3/h = 0.47 l/s = 62.43 Lbs.H2O/Min.
    1 dm3(litre)/s = 10-3 m3/s = 3.6 m3/h = 0.03532 ft3/s = 2.1189 ft3/min (cfm) = 13.200 Imp.gal (UK)/min = 15.852 gal (US)/min = 792 Imp. gal (UK)/h
    1 dm3(litre)/s = 60 litre/min = 3,600 litre/h
    1 ft3/s = 0.0283168 m3/s = 101.9 m3/h = 28.32 dm3(litre)/s = 60 ft3/min = 373.7 Imp.gal (UK)/min = 448.9 gal (US)/min
    1 Imp.gal (UK)/min = 7.57682×10-5 m3/s = 0.273 m3/h = 0.0758 dm3(litre)/s = 2.675×10-3 ft3/s = 0.1605 ft3/min = 1,201 gal (US)/min
    1 gal (US)/min =6.30888×10-5 m3/s = 0.227 m3/h = 0.06309 dm3(litre)/s = 2.228×10-3 ft3/s = 0.1337 ft3/min = 0.8327 Imperial gal (UK)/min



Mbsm.pro, Alimentations secteur sans transformateur, base et calcule

Présentation

La présente page décrit une méthode permettant d’obtenir une basse tension à partir du secteur 230 V, sans faire appel à un transformateurabaisseur style 230 V / 12 V. Il s’agit d’une méthode largement utilisée dans des circuits électroniques basse consommation vendus dans le commerce, tels certaines veilleuses à LED, cafetières électriques (par exemple Senseo) ou anti-taupes à ultrasons.

Avantages

Très économique, pertes de puissance minimes, volume réduit, protection automatique contre les court-circuits accidentels en sortie, tension de sortie stabilisée.

Inconvénients

Risque plus grands d’électrocution (persistance de 230 V dans le montage alimenté, par rapport à la terre), ne convient plus vraiment quand l’intensité demandée dépasse 50 mA.

Avertissements

A lire impérativement avant de continuer. Tout montage alimenté par le secteur présente des risques mortels, si un minimum de bon sens n’est pas respecté. Les montages décrits dans cet article ne possèdent pas de transformateurs d’isolement, et présentent donc un danger supérieur par rapport aux montages qui en possedent un.

Principe

Le principe de base repose sur la capacitance d’un condensateur. La capacitance est simplement la résistance que le condensateur oppose au passage du courant électrique, et qui dépend d’une part de la fréquence du signal qui le traverse, et d’autre part de la valeur (capacité) du condensateur lui-même. En résumé, on se sert du condensateur un peu comme d’une résistance, pour faire chuter une tension et limiter un courant, à une fréquence bien précise.

alim_sans_transfo_001z

Mais la formule R = U / I que l’on utilise pour calculer la valeur d’une résistance en fonction de la chute de tension qu’elle doit provoquer sous un courant donné, ne convient pas (voir page Abaissement tension). Au lieu de celà, nous devons utiliser une formule où apparaît un terme lié à la fréquence de la tension alternative à abaisser (50 Hz du secteur 230 V, en ce qui nous concerne).

Première façon de calculer

Cette première formule permet d’exprimer directement la réactance du condensateur en fonction de sa valeur et de la fréquence du signal qui le traverse :

Xc = 1 / (wc)

où Xc est la capacitance en ohms,
w est la pulsation (lire oméga, égale à 2 * Pi * Freq, Freq en Hertz)
et C est la valeur du condensateur en Farad.
La formule peut donc aussi s’écrire de la façon suivante :

Xc = 1 / (2 * Pi * F * c)

où Xc est la capacitance en ohms,
Pi = 3.14 (manquerait plus que ça change),
F est la fréquence en Hertz,
et C est la valeur du condensateur en Farad.
A la fréquence de 50 Hz, qui est celle du réseau EDF, le condensateur permet de laisser passer un courant de quelques mA par “paquet” de 100 nF.

Exemple N° 1
Usage d’un condensateur de 470 nF (0.00000047 Farad) à la fréquence de 50 Hz :
Xc = 1 / (2 * 3.14 * 50 * 0.00000047) = 6776 ohms
Si tension d’entrée = 230 V et tension de sortie = 12 V, alors
I = (230 – 12) / 6776 = 32 mA

Exemple N° 2
Usage d’un condensateur de 1,7 uF (0.0000017 Farad) à la fréquence de 50 Hz :
Xc = 1 / (2 * 3.14 * 50 * 0.0000017) = 1873 ohms
Si tension d’entrée = 230 V et tension de sortie = 24 V, alors
I = (230 – 24) / 1873 = 110 mA

Exemple N° 3
Usage d’un condensateur de 1 uF (0.000001 Farad) à la fréquence de 50 Hz :
Xc = 1 / (2 * 3.14 * 50 * 0.000001) = 3184 ohms
Si tension d’entrée = 230 V et tension de sortie = 24 V, alors
I = (230 – 24) / 3184 = 65 mA

Exemple N° 4
Usage d’un condensateur de 1 uF (0.000001 Farad) à la fréquence de 50 Hz :
Xc = 1 / (2 * 3.14 * 50 * 0.000001) = 3184 ohms
Si tension d’entrée = 230 V et tension de sortie = 0 V (court-circuit), alors
I = (230 – 0) / 3184 = 72 mA
Par rapport à l’exemple N° 3 (même valeur de condensateur), on constate que le courant est à peine supérieur et qu’il ne prend pas des proportions extrêmes. On a en quelque sorte une limitation de courant naturelle.

Deuxième façon de calculer

Calcul direct de la valeur du condensateur, en connaissant tension de sortie U et courant de sortie I désirés :

C = I / (2 * 3.14 * 50 * (230 – U))

Pour le réseau 230 V / 50 Hz, la formule peut être simplifiée de la façon suivante :

C = I / (314 * (230 – U))

où C est la valeur du condensateur en Farad,
I est le courant maximal de sortie désiré en Ampères
et U est la tension de sortie désirée en Volts

Exemple N° 1
On veut U = 12 V et I = 10 mA
C = 0.01 / (314 * (230 – 12))
C = 146 nF (on prend la valeur normalisée de 150 nF)

Exemple N° 2
On veut U = 0 V (court-circuit, quelle drôle d’idée) et I = 40 mA
C = 0.04 / (314 * 230)
C = 554 nF (valeur normalisée la plus proche : 560 nF)

Exemple N° 3
On veut U = 24 V et I = 110 mA
C = 0.11 / (314 * (230 – 24))
C = 1,7 uF (valeur normalisée 2,2 uF, ou mise en parallèle de 1 uF avec 680 nF)

On peut aussi retourner la formule pour connaître le courant max en fonction de la valeur du condensateur :

I = 2 * 3.14 * F * C * Uc

ou en simplifié pour le réseau 230 V / 50 Hz :

I = 314 * C * Uc

où Uc correspond à la tension aux bornes du condensateur chuteur (230 V – tension de sortie désirée)

Exemple N° 4
On veut connaitre I max pour une tension de sortie U de 12 V, si on utilise un condensateur de 1 uF
I = 314 * 0.000001 * (230 – 12) = 68 mA

Remarques :
– La tension secteur utilisée dans les calculs est bien 230 V qui est la valeur efficace, et non 324 V qui est la tension crête, car au niveau du condensateur, on travaille encore en alternatif.
– Du fait des arrondis appliqués dans les formules précédentes, vous pouvez trouver des valeurs légèrement différentes selon la méthode de calcul utilisée. Le principal étant tout de même de trouver des ordres de grandeur corrects (la formule de la deuxième façon de calculer, publiée avant le 12/09/2009, était fausse – voire Corrections et remarques en fin de page).

Mise en pratique

Le schéma suivant, qui met en oeuvre un condensateur pour abaisser le courant dans une LED, doit donc fonctionner.

alim_sans_transfo_001a

Oui, il fonctionne. Une fois, deux fois, puis à la troisième mise sous tension, pouf, plus de LED. Et encore vous aurez bien de la chance si la LED tient la première fois. Pourquoi ? Parce qu’un condensateur qui n’est pas en service pendant un certain temps, se décharge. Ce qui veut dire que la tension à ses bornes devient très faible ou nulle au bout d’un moment. Cela signifie également qu’on peut alors le considérer comme un court-circuit. Et si on met en service le montage précédent au moment même où l’onde secteur est à son maximum (plus de 310 V crête), la LED voit cette tension à ses bornes, ce qui provoque une surintensité brêve et énorme, de plusieurs ampères. En général, une LED, même plus robuste que la moyenne, à du mal à digérer ce type de traitement. Ce montage est pour cette raison dangeureux, et ne doit pas être réalisé tel quel ! Mais cela n’est qu’un problème parmi d’autres. La LED est un composant polarisé, qui ne fonctionne que si on lui applique une tension continue, et ce dans le bon sens. Une tension alternative est une tension dont l’amplitude varie et dont le sens (la polarité) change sans arrêt, et la LED ne s’allume donc qu’une alternance sur deux. Bon, allez-vous dire, cela reste du 50 Hz et le clignotement sera donc invisible à l’oeil humain du fait de sa persistance rétinienne. Et c’est vrai. Mais la LED n’aime pas trop se trouver avec une tension inverse (tension à l’envers) élevée. La tension inverse supportée avant claquage est de l’ordre de quelques volts seulement, et on peut se douter qu’une tension de quelques 300 volts dépasse légèrement la limite autorisée. Il convient donc dans un premier temps de “bloquer” les alternances non supportées par la LED, ce qui est possible grace à l’adjonction d’une simple diode, comme le montre le montage suivant.

alim_sans_transfo_001b

Maintenant, la LED ne reçoit plus de tension inverse trop élevée, car lors des alternances négatives, c’est la diode D2 (que nous venons d’ajouter) qui conduit. Et quand elle conduit, la tension à ses bornes est inférieure à 1 V, ce qui est bien en dessous de la tension inverse max tolérée par une LED. Cette dernière n’a donc plus de raison de griller. Hum, avez-vous donc déjà oublié le pic de courant qui peut se produire à la mise sous tension ? Le schéma suivant montre qu’avec une simple résistance additionnelle (R1), on résout ce problème potentiel (notons en même temps que la valeur du condensateur C1 a été réduite à 390 nF pour descendre à 10 mA environ le courant dans la LED).

alim_sans_transfo_001c

La résistance R1 limite l’appel de courant quand le condensateur est déchargé. Sa valeur doit être déterminée en fonction de la capacité du condensateur et de la pointe de courant que l’on accèpte, mais de manière générale, on estime que sa valeur doit être de l’ordre de
R = 3 / I (c’est une formule déterminée de façon empirique)
avec R en ohms et I en ampères
Exemple
Si I max = 10 mA (0.01 A), alors
R = 3 / 0.01 = 300 ohms

Remarque : dans certains montages, on tolère une pointe de courant bien supérieure à la valeur du courant nominal, car la pointe est brêve et la dissipation thermique qui en résulte n’est pas toujours dangeureuse. Par exemple, une LED dont le courant nominal est de 20 mA, peut très bien accepter une surintensité de 200 mA si elle est occasionnelle, ou si l’intervalle entre chaque surintensité est grand devant la durée de ces dernières. Si on est sérieux, on se documente sur les capacités du circuit à alimenter, pour connaître ses limites extrêmes.

Voilà donc un montage qui commence à tenir la route. Cependant, nous n’avons pas encore de tension stabilisée en sortie (au niveau de la LED), et les fluctuations de la tension du secteur peuvent provoquer des (petites) variations de courant que l’on ne souhaite pas (même si dans l’exemple présent ce n’est pas si critique que ça). S’il est possible d’utiliser un régulateur de tension de type LM78xx (par exemple régulateur 12 V tel que LM7812), il reste toutefois plus économique et moins encombrant de faire appel à une diode zener. Rappelons que le courant de sortie maximal que l’on attend de ce genre de montage ne peut guère dépasser quelques dizaines de mA. Voici donc un nouveau schéma, dans lequel apparait une diode zener chargée de limiter l’amplitude de sortie à un maximum de 12 V.

alim_sans_transfo_001d

Là encore, le système semble fonctionner puisque la LED D1 s’allume. Mais si nous sommes suffisament curieux et que nous vient à l’idée de mesurer la tension de sortie pour être sûr qu’elle ne dépasse pas 12 V, nous avons droit à une sacrée surprise : la tension atteint quelques 2 V, mais pas plus ! Le choix d’une diode zener serait-il en cause ? Que neni. Une LED est une diode avant tout, et quand elle conduit, la chute de tension ne dépasse pas sa tension nominale, qui ne varie guère même pour une variation de courant assez importante. On peut donc assimiler notre LED à une diode zener de 2 V. Et quand on branche deux diodes zener de valeurs différentes en  parallèle, c’est celle de valeur la plus faible qui a le dernier mot. En d’autres termes, notre diode zener de 12 V (D3) ne sert strictement à rien dans ce montage ! Il convient donc de rectifier le tir, en “isolant” la diode zener de la LED. Avec une résistance, par exemple.

alim_sans_transfo_001e

Cette fois, nous avons bien une tension qui atteint 12 V aux bornes de la diode zener D3, et une tension qui ne dépasse guère les 2 V aux bornes de la LED D1. La résistance R2 cablée entre ces deux composants provoque donc une chute de tension de 10 V (12 V – 2 V). Avec la valeur de 1 kO donnée à cette résistance R2, on en déduit qu’il y circule un courant crête de 10 mA, tout va donc très bien. Bien entendu, si le condensateur C1 avait une valeur plus faible (par exemple de 100 nF), ce courant de 10 mA ne pourrait pas être atteint. Mais en revanche, si le condensateur C1 est de valeur plus élevée (par exemple 1 uF), le courant dans la LED sera toujours de 10 mA car la tension de sortie, imposée par la diode zener D3, ne varie pas (ou très peu). On voit donc que la zener, associée à R2, joue bien un rôle dans la régulation de la tension et du courant de sortie. Cela commence à devenir intéressant, mais constat est fait que la LED reçoit toujours des “bouts” d’alternances, et non une tension continue fixe. Si vous avez quelques notions de base concernant les alimentations secteur linéaires (pas celles à découpage), vous devez savoir que l’ajout d’un condensateur de filtrage pourrait nous rendre bien des services. Et vous avez raison, c’est exactement ce qu’il nous faut. Et hop, un nouveau schéma avec un condensateur en parallèle sur la diode zener !

alim_sans_transfo_001f

A bah ça par exemple, la LED ne s’allume plus ! Et rien n’explose… je n’ai pas l’impression de m’être trompé, pourtant. Revoyons donc ce qui se passe avec ce dernier schéma, lorsque les alternances sont positives, c’est à dire quand la tension sur la phase (Ph) est supérieure à la tension de neutre (N). La tension du secteur parvient à la diode zener et au condensateur C2, et ce dernier se charge sous une tension qui ne peut pas dépasser 12 V. Si maintenant l’alternance change de sens, c’est à dire si la tension sur la phase (Ph) est inférieure à la tension de neutre (N), la diode D2 conduit et… bon sang mais c’est bien sûr ! Elle court-circuite le condensateur C2, qui se décharge donc aussitôt. Et comme la valeur du condensateur C2 est élevée, il n’a pas le temps de se charger entièrement avec une seule alternance (il lui en faut plusieurs). La tension à ses bornes n’a donc jamais le temps de grimper. Si on réduit sa valeur à 1 uF, la LED s’allume bien, mais nous nous retrouvons à nouveau avec des demi-alternances, et point de tension continue. La solution ? Isoler la diode zener D3 et le condensateur de filtrage C2 du secteur, quand ce dernier est sur son alternance négative. En ajoutant une diode, comme ça :

alim_sans_transfo_001g

La diode D4 empêche effectivement le condensateur de se décharger lors des alternances négatives. Et cette fois, nous disposons bien d’une tension continue, stabilisée et filtrée, aux bornes de la diode zener D3. Le calcul de C2 répond approximativement à la formule suivante :

C = 200 * (I / U)

ou C est exprimé en uF
I est le courant maximal de sortie désiré en mA
et U est la tension de sortie désirée en Volts

Usage général

Le dernier schéma mis en pratique montre que l’on s’en tire avec peu de composants, même si au fur et à mesure des expériences menées, on pouvait avoir le sentiment qu’on ne s’en sortirait pas, tant il y avait de “problèmes” à résoudre. Finalement, on peut estimer que le schéma suivant peut être utilisé pour d’autres applications que le simple allumage d’une LED, qui vous l’admettrez est tout de même un exercice plus intéressant que le simple calcul d’une résistance chutrice sous une tension continue… Pour vous simplifier la tâche, vous trouverez ci-après un tableau avec quelques valeurs typiques, pouvant servir de base à quelques expérimentations. Clignotant 006, par exemple…

Remarque : les composants du schéma suivant ont été renumérotés par rapport aux schémas précédents, pour tenir compte du retrait de la LED.

alim_sans_transfo_001h
Sortie 12 V / 10 mA

Tension
Vout
Courant
Iout
C1
(voir note 1)
R1
(1 W)
D3
(400 mW)
C2
(voir note 2)
5 V 20 mA 820 nF 150 5,1 V 1000 uF / 16 V
9 V 10 mA 390 nF 300 9 V 220 uF / 16 V
12 V 40 mA 1,5 uF 75 12 V 680 uF / 16 V
15 V 15 mA 680 nF 200 15 V 220 uF / 25 V
24 V 5 mA 180 nF 600 24 V 47 uF / 40 V

Note 1 : Le condensateur C1 doit impérativement être de classe X2, tension de service 250 V alternatif ou 400 V continu (ou encore mieux 400 V alternatif ou 630 V continu). Si vous aves besoin d’une valeur élevée que vous ne trouvez pas, câblez plusieurs condensateurs en parallèle pour additionner leur valeur.
Note 2 : Le condensateur C2 doit toujours avoir une tension de service supérieure à la tension de sortie désirée.

Usage d’un pont de diodes

L’usage d’un pont de diode est tout à fait possible, c’est d’ailleurs ce que j’ai fait dans ma lampe 230 V à LED.

bases_alim_sans_transfo_001l

Le rendement de ce circuit est meilleur puisqu’on utilise les deux alternances du secteur, ce qui n’était pas le cas avec les montages précédents. Il est évident que pour un montage qui consomme peu, la notion du rendement reste toute relative. Le calcul de C1 ne change pas, c’est toujours lui qui limite le courant disponible en sortie. C2 contribue au filtrage de la tension redressée par le pont de diodes constitué de D1 à D4, et la diode zener D5 stabilise la tension de sortie à une valeur voisine de 12 V (ou autre valeur de tension, à vous de choisir). Il est possible de se passer de la diode zener D5 si le circuit alimenté (relié entre Vout et masse 0 V) ne craint pas des petites crêtes de tension (limitation de courant dans tous les cas assuré par C1), mais dans ce cas attention : il convient d’une part de dimensionner plus haut la tension de service du condensateur C2 et d’autre part d’utiliser pour les diodes D1 à D4 des modèles qui vont bien. Les classiques 1N4007 (1000 V / 1 A) conviennent très bien dans tous les cas. Si vous avez le moindre doute, laisser la diode zener D5 en place.

Ajout d’un régulateur de tension

On peut dans certains cas avoir besoin d’une tension de sortie aussi bien régulée que celle que l’on obtient avec une alimentation traditionnelle à transformateur équipée d’un régulateur de tension intégré. Il est tout à fait possible de monter un tel régulateur de tension sur une alimentation secteur sans transformateur, comme le montre le schéma suivant :

bases_alim_sans_transfo_001k

Ce montage permet de débiter un courant de quelques 40 mA. Il faut noter que quelques mA sont déjà “bouffés” par le régulateur lui-même, qui consomme même si on ne s’en sert pas. Vous pouvez bien entendu modifier la valeur de la diode zener et le type de régulateur, afin de disposer d’une tension de sortie autre que 12 V. Pour la diode zener, choisissez un modèle dont la tension de service est au moins supérieure de 3 V à la tension de sortie du régulateur, si ce dernier est un modèle classique (chute de tension de 3 V au moins pour une régulation correcte). Si vous optez pour un régulateur de tension à faible chute de tension (LDO), vous pourrez alors grignoter quelques mA supplémentaire en sortie en conservant toujours une bonne régulation.
Remarque : en adoptant des condensateurs de 2,2 uF pour C1 et C1′, le courant de sortie utile peut grimper jusqu’à 55 mA, voire 60 mA.

Condensateur ou résistance chutrice ?

J’ai vu plusieurs fois des alimentations secteur sans transformateur où aucun condensateur n’était utilisé en tant qu’élément abaisseur de tension / courant (dans des vieux jeux de lumière, dans des afficheurs de température à LED, entre autres). Certains auteurs préfèrent utiliser des résistances de puissance pour abaisser la tension. Cela est bien entendu possible, mais il faut alors connaitre assez précisement la consommation du montage qui tire son énergie de ce type d’alimentation, et il faut bien entendu choisir des résistances de puissance capable de supporter en continu une chute de tension importante. Le montage suivant est un exemple de ce qu’on peut faire avec des résistances chutrices, sortie double +15 V et +12 V.

bases_alim_sans_transfo_001j

Contrairement à ce qu’on pourrait peut-être penser, ce schéma n’est pas capable de fournir un courant beaucoup plus important que son homologue à condensateur. On est en effet assez vite limité par la dissipation de puissance des résistances R1 à R4, qui au final, et pour une consommation similaire, prennent autant – sinon plus – de place. Ces résistances, qui peuvent chauffer pas mal, doivent être espacées du circuit imprimé d’au moins 5 mm à 10 mm pour laisser l’air circuler librement, et le boîtier “de rangement” doit être suffisement aéré. Les résistances chauffent mais pas le condensateur, à vous de voir.

Lien entre terre et masse ?

Dans les montages qui précèdent, vous aurez noté la mise à la masse du fil de neutre qui vient de la prise secteur 230 Vac. Il faut noter dans ce cas que la masse ne doit pas être reliée à la terre, et encore moins à un boîtier métal !!! Dans le meilleur des cas vous vous exposeriez à une disjonction au départ énergie, et dans le cas le plus malheureux l’utilisateur serait vite “refroidi” en cas de contact direct !

Circuits intégrés spécialisés

Certains fabricants ont sorti des circuits intégrés permettant de passer “directement” de la tension du réseau 110 Vac ou 230 Vac à une basse tension continue. Quelques uns sont listés ci-dessous :
– MAX610 (Maxim) – Sortie +1,3 Vdc à 15 Vdc – 50 mA
– HIP5600 (Harris) – Sortie +1,2 Vdc à +50 Vdc – 30 mA max
– HV2405E (Harris) – Sortie +5 Vdc à +24 Vdc – 50 mA max